MODEL
|
PS-35-3.3
|
PS-35-5
|
PS-357.5
|
PS-35-12
|
OUTPUT
|
DC VOLTAGE
|
3.3V
|
5V
|
7.5V
|
12V
|
RATED CURRENT
|
6A
|
6A
|
4.7A
|
3A
|
CURRENT RANGE
|
0~6A
|
0~6A
|
0~4.7A
|
0~3A
|
RATED POWER (max.)
|
19.8W
|
30W
|
35.25W
|
36W
|
RIPPLE & NOISE (max.) Note.2
|
80mVp-p
|
100mVp-p
|
100mVp-p
|
120mVp-p
|
VOLTAGE ADJ. RANGE
|
3.14~3.63V
|
4.75~5.5V
|
7.13~8.25V
|
10.8~13.2V
|
VOLTAGETOLERANCENote.3
|
2.0%
|
2.0%
|
2.0%
|
1.0%
|
LINE REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
LOADREGULATIONNote.3
|
1.0%
|
1.0%
|
1.0%
|
0.5%
|
SETUP, RISE TIME
|
1200ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
|
HOLD UP TIME
|
50ms/230VAC 10ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 264VAC 127 ~ 370VDC
|
FREQUENCY RANGE
|
47 ~ 440Hz
|
EFFICIENCY (Typ.)
|
70%
|
78%
|
80%
|
81%
|
AC CURRENT (Typ.)
|
0.75A/115VAC 0.5A/230VAC
|
INRUSH CURRENT (Typ.)
|
COLD START 45A/230VAC 23A/115VAC
|
LEAKAGE CURRENT
|
<2mA / 240VAC
|
PROTECTION
|
OVER LOAD
|
105~150% rated output power (3.3V:105~160% rated output power)
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
OVER VOLTAGE
|
3.8~4.95V
|
5.75~6.75V
|
8.63~10.5V
|
13.8~16.2V
|
Protection type : Shut down o/p voltage, re-power on to recover
|
ENVIRONMENT
|
WORKING TEMP.
|
-20 ~ +65oC (Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-20 ~ +85oC , 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.05%/oC (0 ~ 50oC )
|
VIBRATION
|
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
SAFETY &EMC(Note 4)
|
SAFETY STANDARDS
|
UL60950, TUV EN60950-1 Approved
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55022 (CISPR22) Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2,-3
|
EMS
IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
|
MTBF
|
588.8Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
101.5*50.8*24mm (L*W*H)
|
PACKING
|
0.124Kg; 96pcs/12.9Kg/08CUFT
|
NOTE
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
|