MODEL
|
RPS-50-3.3
|
RPS-50-5
|
RPS-50-12
|
RPS-50-15
|
RPS-50-24
|
RPS-50-48
|
OUTPUT
|
DC VOLTAGE
|
3.3V
|
5V
|
12V
|
15V
|
24V
|
48V
|
RATED CURRENT
|
10A
|
10A
|
4.2A
|
3.4A
|
2.1A
|
1.1A
|
CURRENT RANGE
|
0 ~ 12A
|
0 ~ 12A
|
0 ~ 5A
|
0 ~ 4.1A
|
0 ~ 2.5A
|
0 ~ 1.3A
|
RATED POWER (max.)
|
33W
|
50W
|
50.4W
|
51W
|
50.4W
|
52.8W
|
PEAK LOAD(10sec.)
|
39.6W
|
60W
|
60W
|
61.5W
|
60W
|
62.4W
|
RIPPLE & NOISE
|
50mVp-p
|
50mVp-p
|
80mVp-p
|
80mVp-p
|
80mVp-p
|
100mVp-p
|
VOLTAGE ADJ. RANGE
|
3 ~ 3.6V
|
4.5 ~ 5.5V
|
10.8 ~ 13.2V
|
13.5 ~ 16.5V
|
21.6 ~ 27.2V
|
43.2 ~ 52.8V
|
VOLTAGE TOLERANCE
|
3.0%
|
3.0%
|
2.0%
|
2.0%
|
1.0%
|
1.0%
|
LINE REGULATION
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
LOAD REGULATION
|
3.0%
|
3.0%
|
2.0%
|
2.0%
|
1.0%
|
1.0%
|
SETUP, RISE TIME
|
100ms, 40ms/230VAC 100ms, 40ms/115VAC at full load
|
HOLD UP TIME
|
70ms/230VAC 12ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 264VAC 127 ~ 370VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
EFFICIENCY (Typ.)
|
75%
|
81%
|
82%
|
84%
|
85%
|
86%
|
AC CURRENT (Typ.)
|
115VAC
|
0.9A
|
1.2A
|
230VAC
|
0.6A
|
0.8A
|
INRUSH CURRENT
|
COLD START 18A/115VAC 35A/230VAC
|
LEAKAGE CURRENT
|
<1mA / 240VAC
|
PROTECTION
|
OVER LOAD
|
122 ~ 160% rated output power
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
OVER VOLTAGE
|
3.8 ~ 4.45V
|
5.75 ~ 6.75V
|
13.8 ~ 16.2V
|
17.25 ~ 20.25V
|
27.6 ~ 32.4V
|
57.6 ~ 67.2V
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
FUNCTION
|
REMOTE ON/OFF
|
RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V power off
|
ENVIRONMENT
|
WORKING TEMP.
|
-20 ~ +70oC (Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-40 ~ +85oC , 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.04%/ oC (0 ~ 50oC )
|
VIBRATION
|
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
SAFETY &EMC
|
SAFETY STANDARDS
|
UL60950-1, TUV EN60950-1 approved
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55022 (CISPR22) Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2,-3
|
EMS
IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
|
MTBF
|
341.7Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
195*55*23mm (L*W*H)
|
PACKING
|
0.24Kg; 48pcs/12.5Kg/0.84CUFT
|
NOTE
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf nbsp;parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives.
|