Hangzhou Showland Power Co.,Ltd

MDR-100

MDR-100,
MDR-100
  • Product:
    MDR-100

  • Model Number:


  • Description:
     


    Learn more about products detailed description, pricing and service, Please send mail to us!


96W Single Output Industrial DIN Rail Power Supply MDR-100 series

Features:
*  Universal AC input / Full range
*  Protections: Short circuit / Overload / Over voltage / Over temperature
*  ZCS/ZVS technology to reduce power dissipation
*  Cooling by free air convection
*  Can be installed on DIN rail TS-35/7.5 .or 15
*  DC OK relay contact
*  No load power consumption<1W
*  NEC Class 2, limited power source (for 24V,48V only)
*  LED indicator for power on
*  100% full load burn-in test
*  3 years warranty

Specifications:

MODEL

MDR-100-12

MDR-100-24  

MDR-100-48

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

12V

24V

48V

CURRENT RANGE

  0 ~ 7.5A 

0 ~ 4A       

0 ~ 2A

RATED CURRENT

7.5A

4A

2A

RATED POWER

90W

96W

96W

RIPPLE & NOISE (max.)  Note.2

120mVp-p   

150mVp-p   

200mVp-p

VOLTAGE ADJ. RANGE

12 ~ 15V  

24 ~ 30V

48 ~ 56V

VOLTAGE TOLERANCE

NOTE.3

1.0%

1.0%

1.0%

LINE REGULATION

1.0%

LOAD REGULATION

1.0%

1.0%

1.0%

SETUP, RISE TIME NOTE.5 

3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load

HOLD UP TIME (Typ.)

50ms/230VAC    20ms/115VAC at full load

 

 

 

 

INPUT

VOLTAGE RANGE

85 ~ 264VAC   120 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF 0.95/230VAC   PF  0.98/115VAC at full load

EFFICIENCY (Typ.)

85%

86%

88%

AC CURRENT (Typ.)

1.3A/115VAC  0.8A/230VAC

INRUSH CURRENT (Typ.)

COLD START 30A/115VAC   60A/230VAC

LEAKAGE CURRENT

<1mA / 240VAC

 

 

 

 

PROTECTION

OVER LOAD

105 ~ 150% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

OVER TEMPERATURE

90   10  (RTH2) detect on heatsink of power transistor

Protection type : Shut down o/p voltage, re-power on to recover

OVER VOLTAGE

  15.6 ~ 18V  

31.2 ~ 36V   

57.6 ~ 64.8V

Protection type : Shut down o/p voltage, re-power on to recover

DC OK SIGNAL(MAX.)

Relay contact rating(max.): 30V/1A resistive

ENVIRONMENT

WORKING TEMP.

-10 ~ +60 (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 50 )

VIBRATION

Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6

 

 

 

 

 SAFETY &EMC(

SAFETY STANDARDS

UL508, TUV EN60950-1 approved, design refer to NEC CLASS 2 (for 24V,48V only)

WITHSTAND VOLTAGE  

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC 25 70%RH

EMI CONDUCTION & RADIATION

Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B

HARMONIC CURRENT

Compliance to EN61000-3-2,-3

EMS 

IMMUNITY

Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A

 

OTHERS

MTBF

346K hrs min. MIL-HDBK-217F (25 )

DIMENSION

55*90*100mm (W*H*D)

PACKING  

0.42Kg; 30pcs/13.6Kg/0.82CUFT

 

 

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25     of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets

EMC directives.

5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

6. Deating maybe needed under low input voltages, please check the derating curve for more detail.

 

 

Related Product