20W Single Output Industrial DIN Rail Power Supply M DR-20 series

Features:
*  Universal AC input/Full range
*  Protections: Short circuit / Overload / Over voltage
*  Cooling by free air convection
*  Can be installed on DIN rail TS-35/7.5 .or 15
*  NEC class 2 / LPS compliant
*  Built in DC OK active signal
*  LED indicator for power on
*  No load power consumption<0.75W
*  100% full load burn-in test
*  3 years warranty

Specifications:

MODEL

MDR-20-5 

MDR-20-12

MDR-20-15  

MDR-20-24

 

 

 

 

 

 

 

 

  

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

CURRENT RANGE

0 ~ 3A 

0 ~ 1.67A   

0 ~ 1.34A    

0 ~ 1A

RATED CURRENT

3A

1.67A

1.34A

1A

RATED POWER

15W

20W

20W

24W

RIPPLE & NOISE (max.)  Note.2

80mVp-p    

120mVp-p

120mVp-p   

150mVp-p

VOLTAGE ADJ. RANGE

4.75 ~ 5.5V  

10.8 ~ 13.2V

13.5 ~ 16.5V  

21.6 ~ 26.4V

VOLTAGE TOLERANCE

NOTE.3

2.0%

1.0%

1.0%

1.0%

LINE REGULATION

1.0%

LOAD REGULATION

1.0%

1.0%

1.0%

1.0%

SETUP, RISE TIME NOTE.5 

500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load

HOLD UP TIME (Typ.)

50ms/230VAC    20ms/115VAC at full load

 

 

 

 

INPUT

VOLTAGE RANGE

85 ~ 264VAC   120 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

76%

80%

81%

84%

AC CURRENT (Typ.)

0.55A/115VAC   0.35A/230VAC

INRUSH CURRENT (Typ.)

COLD START 20A/115VAC   40A/230VAC

LEAKAGE CURRENT

<1mA / 240VAC

 

 

 

PROTECTION

OVER LOAD

105 ~ 160% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

5.75 ~ 6.75V   

13.8 ~ 16.2V

17.25 ~ 20.25V

27.6 ~ 32.4V

Protection type : Shut down o/p voltage, re-power on to recover

DC OK ACTIVE SIGNAL(MAX.)

3.75 ~ 6V / 50mA              

9 ~ 13.5V / 40mA

11.5 ~ 16.5V / 40mA

18 ~ 27V / 20mA

 

 

 

ENVIRONMENT

WORKING TEMP.

-20 ~ +70 (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 50 )

VIBRATION

Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6

 

 

 

 

 

 

 

SAFETY &EMC

SAFETY STANDARDS

UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant

WITHSTAND VOLTAGE  

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC

EMI CONDUCTION & RADIATION

Compliance to EN55011,EN55022 (CISPR22), EN61204-3 Class B

HARMONIC CURRENT

Compliance to EN61000-3-2,-3

EMS 

IMMUNITY

Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024,EN61000-6-1,EN61204-3, light industry level, criteria A

 

OTHERS

MTBF

236.9K hrs min. MIL-HDBK-217F (25 )

DIMENSION

22.5*90*100mm (W*H*D)

PACKING  

0.19Kg; 72pcs/14.7Kg/0.91CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25     of ambient temperature.

2Ripple & noisarmeasurea20MHobandwidtbusing a 12twistepair-wirterminatewith a 0.1uf & 47uparallecapacitor.

3Tolerance : includeseutolerancelinregulatioanloaregulation.

4Thpowesuppliconsidered a componenwhicwilbinstalleinto a finaequipmentThfinaequipmenmusbre-confirmethaistilmeetEMdirectives.

5LengtoseutimimeasureacolfirsstartTurninON/OFthpowesupplmaleatincreasothseutime.