75W Single Output Industrial DIN Rail Power Supply DR-75 series
Features:
* Universal AC input / Full range
* Protections:Short circuit / Overload / Over voltage / Over temperature
* Cooling by free air convection
* Can be installed on DIN rail TS-35/7.5 .or 15
* UL 508(industrial control equipment)approved
* LED indicator for power on
* 100% full load burn-in test
* Fix switching frequency at 50KHz
* 3 years warranty
Specifications:
MODEL
|
DR-75-12
|
DR-75-24
|
DR-75-48
|
OUTPUT
|
DC VOLTAGE
|
12V
|
24V
|
48V
|
CURRENT RANGE
|
0 ~ 6.3A
|
0 ~ 3.2A
|
0 ~ 1.6A
|
RATED CURRENT
|
6.3A
|
3.2A
|
1.6A
|
RATED POWER
|
76W
|
76.8W
|
76.8W
|
RIPPLE & NOISE
|
100mVp-p
|
150mVp-p
|
240mVp-p
|
VOLTAGE ADJ. RANGE
|
12 ~ 14V
|
24 ~ 28V
|
48 ~ 53V
|
VOLTAGE TOLERANCE
|
2.0%
|
1.0%
|
1.0%
|
LINE REGULATION
|
0.5%
|
LOAD REGULATION
|
1.0%
|
SETUP, RISE TIME
|
1000ms, 60ms/230VAC 1800ms, 60ms/115VAC at full load
|
HOLD UP TIME
|
60ms/230VAC 12ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
85 ~ 264VAC 120 ~ 370VDC
|
FREQUENCY
|
47 ~ 63Hz
|
POWER FACTOR
|
|
EFFICIENCY
|
76%
|
80%
|
81%
|
AC CURRENT
|
1.6A/115V 0.96A/230V
|
INRUSH CURRENT
|
COLD START 20A/115VAC 40A/230VAC
|
LEAKAGE CURRENT
|
<1mA / 240VAC
|
PROTECTION
|
OVER LOAD
NOTE.6
|
105 ~ 150% rated output power
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed
|
OVER VOLTAGE
|
15 ~ 16.5V
|
29 ~ 34V
|
58 ~ 65V
|
Protection type : Shut down o/p voltage, re-power on to recover
|
OVER TEMP
|
85oC 5 (TSW1) detect on heat sink of power transistor
|
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
|
OTHERS
|
MTBF
|
123.1K hrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
55.5*125.2*100mm (W*H*D)
|
PACKING
|
0.6Kg; 20pcs/13Kg/1.29CUFT
|