MODEL
|
MPD-65A
|
MPD-65B
|
OUTPUT
|
CHANNEL
|
CH1
|
CH2
|
CH1
|
CH2
|
DC VOLTAGE
|
5V
|
12V
|
5V
|
24V
|
RATED CURRENT
|
5.5A
|
2.8A
|
3.5A
|
2A
|
CURRENT RANGE
|
0.4 ~ 7A
|
0.2 ~ 3.2A
|
0.4 ~ 6A
|
0.2 ~ 2.6A
|
RATED POWER
|
61.1W
|
65.5W
|
OUTPUT POWER
|
72W with 18CFM min. Forced air convection
|
RIPPLE & NOISE
|
60mVp-p
|
150mVp-p
|
60mVp-p
|
150mVp-p
|
VOLTAGE ADJ. RANGE
|
CH1:4.5 ~ 5.5V
|
CH1:4.5 ~ 5.5V
|
VOLTAGE TOLERANCE
|
4.0%
|
7.0%
|
4.0%
|
7.0%
|
LINE REGULATION
|
1.0%
|
2.0%
|
1.0%
|
2.0%
|
LOAD REGULATION
|
3.0%
|
4.0%
|
3.0%
|
4.0%
|
SETUP, RISE TIME
|
800ms, 20ms/230VAC 800ms, 20ms/115VAC at full load
|
HOLD UP TIME
|
50ms/230VAC 16ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 264VAC 127 ~ 370VDC
|
FREQUENCY RANGE
|
47 ~ 440Hz
|
EFFICIENCY (Typ.)
|
75%
|
78%
|
AC CURRENT
|
1.6A/115VAC 1A/230VAC
|
INRUSH CURRENT
|
COLD START 20A/115VAC 40A/230VAC
|
LEAKAGE CURRENT
|
<0.3mA / 264VAC
|
PROTECTION
|
OVER LOAD
|
73 ~ 105W rated output power
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
OVER VOLTAGE
|
5.75 ~ 6.75V on CH1
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
ENVIRONMENT
|
WORKING TEMP.
|
-10 ~ +55oC (Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-20 ~ +85oC , 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.04%/oC (0 ~ 50oC ) on +5V output
|
VIBRATION
|
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
SAFETY &EMC
|
SAFETY STANDARDS
|
UL2601-1, TUV EN60601-1, IEC60601-1 approved
|
WITHSTAND VOLTAGE
|
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/P-FG:100M Ohms/500VDC
|
EMI CONDUCTION & RADIATION
|
ompliance to EN55011 (CISPR11) Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2,-3
|
EMS
IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN60601-1-2, medical level, criteria A
|
MTBF
|
291.3Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
127*76*42mm (L*W*H)
|
PACKING
|
0.25Kg; 54pcs/16Kg/1.35CUFT
|
NOTE
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
|