75W Dual Output Medical Type RPD-75 series

Features:
*  Universal AC input/Full range
Low leakage current<200uA
Protections: Short circuit / Overload / Over voltage
Free air convection for rated power and 23.5CFM forced air
convection for peak load
UL60601-1/IEC60601-1/EN60601-1 medical safety approved
Fixed switching frequency at 65KHz
3 years warranty


Specifications:

MODEL

RPD-75A                                           

RPD-75B

OUTPUT

CHANNEL

CH1

CH2

CH1

   CH2

DC VOLTAGE

5V

12V

5V

24V

RATED CURRENT

7A

3A

5A

2A

CURRENT RANGE

1 ~ 9.5A  

0.3 ~ 4A   

1 ~ 6.8A  

0.2 ~ 2.7A

RATED POWER 

71W

73W

PEAK LOAD 

95.5W

98.8W

RIPPLE & NOISE 

80mVp-p   

120mVp-p

80mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

CH1: 4.75 ~ 5.5V                                     

CH1: 4.75 ~ 5.5V

VOLTAGE TOLERANCE  

2.0%

6.0%

2.0%

6.0%

LINE REGULATION

0.5%

1.0%

0.5%

1.0%

LOAD REGULATION 

1.5%

3.0%

1.5%

3.0%

SETUP, RISE TIME  

500ms, 30ms/230VAC     500ms, 30ms/115VAC at full load

HOLD UP TIME

80ms/230VAC      20ms/115VAC at full load

 

 

 

 

INPUT

VOLTAGE RANGE

90 ~ 264VAC   127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

77%

79%

AC CURRENT 

1.5A/115VAC    1A/230VAC

INRUSH CURRENT 

COLD START 25A/115VAC     50A/230VAC

LEAKAGE CURRENT

Earth leakage current <200uA / 264VAC, Patient leakage current <100uA/264VAC

 

PROTECTION

OVER LOAD

140 ~ 180% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

CH1: 5.75 ~ 6.75V                          

Protection type : Shut down o/p voltage, re-power on to recover

 

 

 

ENVIRONMENT

WORKING TEMP.

-20 ~ +70oC (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85oC , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/oC  (0 ~ 45oC ) 

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for  60min. each along X, Y, Z axes

 

 

 

SAFETY &EMC

SAFETY STANDARDS

UL60601-1, TUV EN60601-1, IEC60601-1 approved

WITHSTAND VOLTAGE  

I/P-O/P:4KVAC I/P-FG:1.5KVAC  O/P-FG:1.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC

EMI CONDUCTION & RADIATION

Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B

HARMONIC CURRENT

Compliance to EN61000-3-2,-3

EMS 

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A

MTBF

569.9K hrs min. MIL-HDBK-217F (25 )

DIMENSION

127*76.2*31mm (L*W*H)

PACKING  

0.25Kg; 63pcs/16.7Kg/1.35CUFT

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature.

2Ripple & noisarmeasurea20MHobandwidtbusing a 12twistepair-wirterminatewith a 0.1uf & 47uparallecapacitor.

3Tolerance : includeseutolerancelinregulatioanloaregulation.

4Thpowesuppliconsidered a componenwhicwilbinstalleinto a finaequipmentThfinaequipmenmusbre-confirmethaistilmeetEMdirectives.

5LengtoseutimimeasureacolfirsstartTurninON/OFthpowesupplmaleatincreasothseutime.

 