Features: * Universal AC input / Full range
* Low leakage current<200uA
* Protections: Short circuit / Overload / Over voltage
* Free air convection for rated power and 23.5CFM forced air
* convection for peak load
* UL60601-1/IEC60601-1/EN60601-1 medical safety approved
* Fixed switching frequency at 65KHz
* 3 years warranty
Specifications:
MODEL
RPT-75A
OUTPUT
CHANNEL
CH1
CH2
CH3
DC VOLTAGE
5V
12V
-5V
RATED CURRENT
6A
3A
0.5A
CURRENT RANGE
0.6 ~ 8A
0.2 ~ 4A
0.1 ~ 1A
RATED POWER (max.)
68.5W
PEAK LOAD(10sec.) Note.4
93W
RIPPLE & NOISE (max.) Note.2
80mVp-p
120mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3
2.0%
6.0%
5.0%
LINE REGULATION
0.5%
1.0%
1.0%
LOAD REGULATION Note.3
1.5%
3.0%
1.0%
SETUP, RISE TIME
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
HOLD UP TIME
80ms/230VAC 20ms/115VAC at full load
INPUT
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
AC CURRENT (Typ.)
1.5A/115VAC 1A/230VAC
INRUSH CURRENT (Typ.)
COLD START 25A/115VAC 50A/230VAC
LEAKAGE CURRENT
Earth leakage current <200uA / 264VAC, Patient leakage current <100uA/264VAC
MODEL
RPT-75B
OUTPUT
CHANNEL
CH1
CH2
CH3
DC VOLTAGE
5V
12V
-12V
RATED CURRENT
6A
3A
0.5A
CURRENT RANGE
0.6 ~ 8A
0.2 ~ 4A
0.1 ~ 1A
RATED POWER (max.)
72W
PEAK LOAD(10sec.) Note.4
100W
RIPPLE & NOISE (max.) Note.2
80mVp-p
120mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3
2.0%
6.0%
5.0%
LINE REGULATION
0.5%
1.0%
1.0%
LOAD REGULATION Note.3
1.5%
3.0%
1.0%
SETUP, RISE TIME
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
HOLD UP TIME
80ms/230VAC 20ms/115VAC at full load
INPUT
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
77%
AC CURRENT (Typ.)
1.5A/115VAC 1A/230VAC
INRUSH CURRENT (Typ.)
COLD START 25A/115VAC 50A/230VAC
LEAKAGE CURRENT
Earth leakage current <200uA / 264VAC, Patient leakage current <100uA/264VAC
MODEL
RPT-75C
OUTPUT
CHANNEL
CH1
CH2
CH3
DC VOLTAGE
5V
15V
-15V
RATED CURRENT
6A
2.3A
0.5A
CURRENT RANGE
0.6 ~ 8A
0.1 ~ 3A
0.1 ~ 1A
RATED POWER (max.)
72W
PEAK LOAD(10sec.) Note.4
100W
RIPPLE & NOISE (max.) Note.2
80mVp-p
150mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3
2.0%
8.0%
5.0%
LINE REGULATION
0.5%
1.0%
1.0%
LOAD REGULATION Note.3
1.5%
3.0%
1.0%
SETUP, RISE TIME
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
HOLD UP TIME
80ms/230VAC 20ms/115VAC at full load
INPUT
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
77%
AC CURRENT (Typ.)
1.5A/115VAC 1A/230VAC
INRUSH CURRENT (Typ.)
COLD START 25A/115VAC 50A/230VAC
LEAKAGE CURRENT
Earth leakage current <200uA / 264VAC, Patient leakage current <100uA/264VAC