MODEL
|
NFM-20-3.3
|
NFM-20-5
|
NFM-20-12
|
NFM-20-15
|
NFM-20-24
|
OUTPUT
|
DC VOLTAGE
|
3.3V
|
5V
|
12V
|
15V
|
24V
|
RATED CURRENT
|
4.5A
|
4.4A
|
1.8A
|
1.4A
|
0.92A
|
CURRENT RANGE
|
0 ~ 4.5A
|
0 ~ 4.4A
|
0 ~ 1.8A
|
0 ~ 1.4A
|
0 ~ 0.92A
|
RATED POWER
|
14.85W
|
22W
|
21.6W
|
21W
|
22.08W
|
RIPPLE & NOISE
|
80mVp-p
|
80mVp-p
|
150mVp-p
|
150mVp-p
|
240mVp-p
|
VOLTAGE ADJ.
|
3 ~ 3.63V
|
4.5 ~ 5.5V
|
10.8 ~ 13.2V
|
13.5 ~ 16.5V
|
21.6 ~ 26.4V
|
VOLTAGE TOLERANCE
|
2.0%
|
2.0%
|
1.0%
|
1.0%
|
1.0%
|
LINE REGULATION
|
1.0%
|
1.0%
|
0.5%
|
0.5%
|
0.5%
|
LOAD REGULATION
|
1.0%
|
1.0%
|
0.5%
|
0.5%
|
0.5%
|
SETUP RISE TIME
|
500ms, 20ms/230VAC 500ms, 20ms/115VAC at full load
|
HOLD UP TIME
|
50ms/230VAC 16ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
85 ~ 264VAC 120 ~ 370VDC
|
FREQUENCY
|
47 ~ 440Hz
|
EFFICIENCY
|
71%
|
75%
|
81%
|
83%
|
84%
|
C CURRENT
|
0.6A/115VAC 0.4A/230VAC
|
INRUSH CURRENT
|
COLD START 30A/115VAC 65A/230VAC
|
PROTECTION
|
OVER LOAD
|
Above 105% rated output power
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
OVER VOLTAGE
|
3.8 ~ 4.95V
|
5.75 ~ 6.75V
|
13.8 ~ 16.2V
|
17.25 ~ 20.25V
|
27.6 ~ 32.4V
|
Protection type : Shut off o/p voltage, clamping by zener diode
|
OVER TEMP
|
Tj 145 typically (U1) detect on main control IC
|
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
|
ENVIRONMENT
|
WORKING TEMP.
|
-20 ~ +60 oC(Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-40 ~ +85oC , 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.03%/ oC(0 ~ 50oC
|
VIBRATION
|
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
SAFETY &EMC
|
SAFETY STANDARDS
|
UL60601-1,TUV EN60601-1, IEC60601-1 approved
|
WITHSTAND VOLTAGE
|
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2,-3
|
EMS
IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A
|
MTBF
|
487.8Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
89*51*19.3mm (L*W*H)
|
PACKING
|
0.09Kg; 105pcs/10.5Kg/0.97CUFT
|
NOTE
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specification provided by the IC manufacturer.
|