MODEL
|
D-120A
|
D-120B
|
OUTPUT
|
OUTPUT NUMBER
|
CH1
|
CH2
|
CH1
|
CH2
|
DC VOLTAGE
|
5V
|
12V
|
5V
|
24V
|
CURRENT RANGE
|
2 ~ 12A
|
0.5 ~ 5A
|
2 ~ 10A
|
0.4 ~ 4A
|
RATED CURRENT
|
12A
|
5A
|
6A
|
4A
|
RATED POWER
|
120W
|
126W
|
RIPPLE & NOISE (max.) Note.2
|
60mVp-p
|
120mVp-p
|
60mVp-p
|
150mVp-p
|
VOLTAGE ADJ. RANGE
|
CH1 : 4.75 ~ 5.5V
|
CH1 : 4.75 ~ 5.5V
|
VOLTAGE TOLERANCE
NOTE.3
|
2.0%
|
6.0%
|
2.0%
|
7.0%
|
LINE REGULATION
|
0.5%
|
1.0%
|
0.5%
|
1.0%
|
LOAD REGULATION
|
0.5%
|
5.0%
|
0.5%
|
6.0%
|
SETUP, RISE TIME NOTE.5
|
200ms, 50ms at full load
|
HOLD TIME (Typ.)
|
24ms at full load
|
INPUT
|
VOLTAGE RANGE
|
88 ~ 132VAC/176 ~ 264VAC selected by switch 248 ~ 370VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
EFFICIENCY (Typ.)
|
78%
|
80%
|
AC CURRENT (Typ.)
|
2.2A/115VAC 1.3A/230VAC
|
INRUSH CURRENT (Typ.)
|
COLD START 32A
|
LEAKAGE CURRENT
|
<3.5mA / 240VAC
|
PROTECTION
|
OVER LOAD
|
105 ~ 135% rated output power
|
Protection type : Shut down o/p voltage, re-power on to recover
|
OVER VOLTAGE
|
5V : 5.75 ~ 6.75V
|
Protection type : Shut down o/p voltage, re-power on to recover
|
ENVIRONMENT
|
WORKING TEMP.
|
-10 ~ +60oC (Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-20 ~ +85oC , 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.03%/oC (0 ~ 50oC ) on +5V output
|
VIBRATION
|
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
SAFETY &EMC(Note 4)
|
SAFETY STANDARDS
|
UL60950-1, TUV EN60950-1, CCC GB4943 approved
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/, P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55022 (CISPR22) Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2,-3
|
EMS IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
|
OTHERS
|
MTBF
|
272.8K hrs min. MIL-HDBK-217F
|
DIMENSION
|
199*110*50mm (L*W*H)
|
PACKING
|
0.82Kg; 16pcs/14.2Kg/0.95CUFT
|
NOTE
|
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation
. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
|