40W Single Output Switching Power Supply

Features:
*  Universal AC input / Full  range
*  Protections: Short circuit / Overload / Over voltage
*  Cooling by free air convection
*  100% full load burn-in test
*  Fixed switching frequency at 75KHz
*  2 years warranty

Specifications:

MODEL

S-40-5

S-40-12

S-40-15

S-40-24

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

RATED CURRENT

8A

3.5A

2.8A

1.8A

CURRENT RANGE

0 ~ 8A

0 ~ 3.5A

0 ~ 2.8A

0 ~ 1.8A

RATED POWER

40W

42W

42W

43W

RIPPLE & NOISE 

75mVp-p

100mVp-p

100mVp-p

100mVp-p

VOLTAGE ADJ. RANGE

4.75 ~ 5.5V

10.8 ~ 13.2V

13.5 ~ 16.5V

21.6 ~ 26.4V

VOLTAGE TOLERANCE  

2.0%

1.0%

1.0%

1.0%

LINE REGULATION

0.5%

0.5%

0.5%

0.5%

LOAD REGULATION

1.0%

0.5%

0.5%

0.5%

SETUP, RISE TIME

300ms, 50ms/230VAC    800ms, 50ms/115VAC at full load

HOLD UP TIME 

70ms/230VAC    15ms/115VAC at full load

INPUT

VOLTAGE RANGE

85 ~ 264VAC   120 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

72%/115VAC

76%/115VAC

76%/115VAC

78%/115VAC

AC CURRENT (Typ.)

1.2A/115VAC    0.6A/230VAC

INRUSH CURRENT 

COLD START 25A/115VAC     50A/230VAC

LEAKAGE CURRENT

<1mA / 240VAC

PROTECTION

OVERLOAD

105 ~ 150% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

5.75 ~ 6.75V

13.8 ~ 16.2V

17.25 ~ 20.25

27.6 ~ 32.4V

Protection type : Hiccup mode, recovers automatically after fault condition is removed

ENVIRONMENT

WORKING TEMP.

-10 ~ +60 (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP HUMIDITY

-20 ~ +85 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/  (0 ~ 50 )

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for  60min. each along X, Y, Z axes

SAFETY &EMC

SAFETY STANDARDS

UL1012, UL60950-1, TUV EN60950-1 approved

WITHSTAND VOLTAGE  

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC

EMI CONDUCTION & RADIATION

Compliance to EN55022 (CISPR22) Class B

HARMONIC CURRENT

Compliance to EN61000-3-2,-3

EMS 

IMMUNITY

Compliance to EN61000-4-2,3,4,5; ENV50204, EN55024, light industry level,  criteria A

OTHERS

MTBF

314.1K hrs min. MIL-HDBK-217F (25 )

DIMENSION

129*98*38mm (L*W*H)

PACKING  

0.44Kg; 30pcs/13.9Kg/0.86CUFT

NOTE

1AlparameterNOspeciallmentionearmeasurea230VAinputrateloaan25     oambientemperature.

2Ripple & noisarmeasurea20MHobandwidtbusing a 12twistepair-wirterminatewith a 0.1uf & 47uparallecapacitor.

3Tolerance : includeseutolerancelinregulatioanloaregulation.

4Thpowesuppliconsidered a componenwhicwilbinstalleinto a finaequipmentThfinaequipmenmusbre-confirmethaistilmeets