Features:
* Universal AC input / Full range (up to 305VAC)
* Built-in active PFC function
* Protections: Short circuit / Overload / Over voltage / Over temperature
* Cooling by free air convection
* OCP point adjustable through output cable .or internal potential meter
* IP67 / IP65 design for indoor .or outdoor installations
* Optional dimming function (1~10Vdc .or PWM signal .or resister) Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting
* Suitable for dry / damp / wet location and outdoor application
* 5 years warranty
Specifications:
MODEL
|
HLG-320H-12
|
HLG-320H-15
|
HLG-320H-20
|
HLG-320H-24
|
OUTPUT
|
DC VOLTAGE
|
12V
|
15V
|
20V
|
24V
|
C&C REGION
|
6 ~12V
|
7.5 ~ 15V
|
10 ~ 20V
|
12 ~ 24V
|
RATED CURRENT
|
22A
|
19A
|
15A
|
13.34A
|
RATED POWER
|
264W
|
285W
|
300W
|
320.2W
|
RIPPLE & NOISE
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
VOLTAGE ADJ.
|
10.8~13.5V
|
13.5~ 17V
|
17 ~ 22V
|
22 ~ 27V
|
CURRENT ADJ.RANGE
|
Can be adjusted by internal potential meter .or through output cable
|
11 ~ 22A
|
9.5 ~ 19A
|
7.5 ~ 15A
|
6.67~13.34A
|
VOLTAGE TOLERANCE
|
2.5%
|
2.0%
|
1.0%
|
1.0%
|
LINE REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
LOAD REGULATION
|
2.0%
|
1.5%
|
1.0%
|
0.5%
|
SETUP RISE TIME
|
2500ms, 80ms at full load 230VAC /115VAC
|
HOLD UP TIME
|
15ms at full load 230VAC / 115VAC
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 305VAC 127 ~ 431VDC
|
FREQUENCY
|
47 ~ 63Hz
|
POWER FACTOR
|
PF 0.95/230VAC PF 0.98/115VAC at full load and rated output voltage PF 0.9 at 50 ~ 100% load
|
EFFICIENCY
|
92%
|
92%
|
93%
|
94%
|
AC CURRENT
|
4A / 115VAC 2A / 230VAC 1.8A / 277VAC
|
INRUSH CURRENT
|
COLD START 75A/230VAC
|
LEAKAGE CURRENT
|
<0.75mA / 277VAC m
|
OTHERS
|
MTBF
|
Khrs min. MIL-HDBK-217F
|
DIMENSION
|
252*90*42mm (L*W*H)(HLG-320H-Blank/A/B) 256*90*42mm (L*W*H)(HLG-320H-C)
|
PACKING
|
Kg
|
MODEL
|
HLG-320H-30
|
HLG-320H-36
|
HLG-320H-42
|
HLG-320H-48
|
HLG-320H-54
|
OUTPUT
|
DC VOLTAGE
|
30V
|
36V
|
42V
|
48V
|
54V
|
C&C REGION
|
15 ~ 30V
|
18 ~ 36V
|
21 ~ 42V
|
24 ~ 48V
|
27 ~ 54V
|
RATED CURRENT
|
10.7A
|
8.9A
|
7.65A
|
6.7A
|
5.95A
|
RATED POWER
|
321W
|
320.4W
|
321.3W
|
321.6W
|
321.3W
|
RIPPLE & NOISE
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
VOLTAGE ADJ.
|
27 ~ 33V
|
33 ~ 40V
|
38 ~ 46V
|
43 ~ 53V
|
49 ~ 58V
|
CURRENT ADJ.RANGE
|
Can be adjusted by internal potential meter .or through output cable
|
5.35~10.7A
|
4.45~8.9A
|
3.8~7.65A
|
3.35~6.7A
|
2.97~5.95A
|
VOLTAGE TOLERANCE
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
LINE REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
LOAD REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
SETUP RISE TIME
|
2500ms, 80ms at full load 230VAC /115VAC
|
HOLD UP TIME
|
15ms at full load 230VAC / 115VAC
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 305VAC 127 ~ 431VDC
|
FREQUENCY
|
47 ~ 63Hz
|
POWER FACTOR
|
PF 0.95/230VAC PF 0.98/115VAC at full load and rated output voltage PF 0.9 at 50 ~ 100% load
|
EFFICIENCY
|
94%
|
94%
|
94.5%
|
95%
|
95%
|
AC CURRENT
|
4A / 115VAC 2A / 230VAC 1.8A / 277VAC
|
INRUSH CURRENT
|
COLD START 75A/230VAC
|
LEAKAGE CURRENT
|
<0.75mA / 277VAC m
|
OTHERS
|
MTBF
|
Khrs min. MIL-HDBK-217F
|
DIMENSION
|
252*90*42mm (L*W*H)(HLG-320H-Blank/A/B) 256*90*42mm (L*W*H)(HLG-320H-C)
|
PACKING
|
Kg
|