Features:
* Universal AC input / Full range
* Built-in active PFC function
* High efficiency up to 94%
* Protections: Short circuit / Overload / Over voltage / Over temperature
* Cooling by free air convection
* OCP point adjustable through output cable .or internal potential meter
* IP67 / IP65 design for indoor .or outdoor installations
* Three in one dimming function (1~10Vdc .or PWM signal .or resistor) Suitable for LED lighting and street lighting applications
* Compliance to worldwide safety regulations for lighting
* Suitable for dry / damp / wet locations
* 5 years warranty
Specification:
MODEL
|
HLG-120-12
|
HLG-120-15
|
HLG-120-20
|
HLG-120-24
|
HLG-120-30
|
HLG-120-36
|
HLG-120-42
|
HLG-120-48
|
HLG-120-54
|
OUTPUT
|
DC VOLTAGE
|
12V
|
15V
|
20V
|
24V
|
30V
|
36V
|
42V
|
48V
|
54V
|
C&C REGION
|
6 ~12V
|
7.5 ~ 15V
|
10 ~ 20V
|
12 ~ 24V
|
15 ~ 30V
|
18 ~ 36V
|
21 ~ 42V
|
24 ~ 48V
|
27 ~ 54V
|
RATED CURRENT
|
10A
|
8A
|
6A
|
5A
|
4A
|
3.4A
|
2.9A
|
2.5A
|
2.3A
|
RATED POWER
|
120W
|
120W
|
120W
|
120W
|
120W
|
122.4W
|
121.8W
|
120W
|
124.2W
|
RIPPLE & NOISE
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
VOLTAGE ADJ.RANGE
|
10.8~
13.5V
|
13.5~ 17V
|
17 ~ 22V
|
22 ~ 27V
|
27 ~ 33V
|
33 ~ 40V
|
38 ~ 46V
|
43 ~ 53V
|
49 ~ 58V
|
CURRENT ADJ.RANGE
|
Can be adjusted by internal potential meter .or through output cable
|
5 ~ 10A
|
4 ~ 8A
|
3 ~ 6A
|
2.5 ~ 5A
|
2 ~ 4A
|
1.7 ~ 3.4A
|
1.4 ~ 2.9A
|
1.2 ~ 2.5A
|
1.1 ~ 2.3A
|
VOLTAGE TOLERANCE
|
2.5%
|
2.0%
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
LINE REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
LOAD REGULATION
|
2.0%
|
1.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
SETUP, RISE TIME
|
2500ms, 50ms at full load 230VAC / 115VAC ; B type 2500ms, 200ms at 95% load 230VAC / 115VAC
|
HOLD UP TIME
|
16ms at full load 230VAC / 115VAC
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 264VAC 127 ~ 370VDC
|
FREQUENCY
|
47 ~ 63Hz
|
POWER FACTOR
|
PF 0.95/230VAC PF 0.98/115VAC at full load and rated output voltage PF 0.9 at 50 ~ 100% load
|
EFFICIENCY
|
92%
|
92%
|
93.5%
|
94%
|
94%
|
94%
|
94%
|
94%
|
94%
|
AC CURRENT
|
1.4A / 115VAC 0.6A / 230VAC
|
INRUSH CURRENT
|
COLD START 75A/230VAC
|
LEAKAGE CURRENT
|
<0.75mA / 240VAC m
|
OTHERS
|
MTBF
|
192.2Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
220*68*38.8mm (L*W*H)
|
PACKING
|
1.12Kg; 12pcs/14.4Kg/0.76CUFT
|