Features:
* Universal AC input / Full range (up to 305VAC)
* Built-in active PFC function
* High efficiency up to 94%
* Protections: Short circuit / Overload / Over voltage / Over temperature
* Cooling by free air convection
* OCP point adjustable through output cable .or internal potential meter
* IP67 / IP65 design for indoor .or outdoor installations
* Three in one dimming function (1~10Vdc .or PWM signal .or resistor) Suitable for LED lighting and street lighting applications
* Compliance to worldwide safety regulations for lighting
* Suitable for dry / damp / wet locations
* 5 years warranty
Specifications:
MODEL
|
HLG-150H-12
|
HLG-150H-15
|
HLG-150H-20
|
HLG-150H-24
|
OUTPUT
|
DC VOLTAGE
|
12V
|
15V
|
20V
|
24V
|
C&C REGION
|
6 ~12V
|
7.5 ~ 15V
|
10 ~ 20V
|
12 ~ 24V
|
RATED CURRENT
|
12.5A
|
10A
|
7.5A
|
6.3A
|
RATED POWER
|
150W
|
150W
|
150W
|
151.2W
|
RIPPLE & NOISE
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
VOLTAGE ADJ.RANGE
|
10.8~13.5V
|
13.5~ 17V
|
17 ~ 22V
|
22 ~ 27V
|
CURRENT ADJ.RANGE
|
Can be adjusted by internal potential meter .or through output cable
|
7.5~12.5A
|
6 ~ 10A
|
4.5 ~ 7.5A
|
3.8 ~ 6.3A
|
VOLTAGE TOLERANCE
|
2.5%
|
2.0%
|
1.0%
|
1.0%
|
LINE REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
LOAD REGULATION
|
2.0%
|
1.5%
|
1.0%
|
0.5%
|
SETUP, RISE TIME
|
2500ms, 50ms at full load 230VAC / 115VAC ; B type 2500ms, 200ms at 95% load 230VAC / 115VAC
|
HOLD UP TIME
|
16ms at full load 230VAC / 115VAC
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 305VAC 127 ~ 431VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
POWER FACT.or
|
PF 0.95/230VAC PF 0.98/115VAC at full load and rated output voltage PF 0.9 at 60 ~ 100% load
|
EFFICIENCY
|
91.5%
|
92%
|
93%
|
93%
|
AC CURRENT
|
1.7A / 115VAC 0.75A / 230VAC 0.7A / 277VAC
|
INRUSH CURRENT
|
COLD START 75A/230VAC
|
LEAKAGE CURRENT
|
<0.75mA / 277VAC m
|
OTHERS
|
MTBF
|
192.2Khrs min. MIL-HDBK-217F
|
DIMENSION
|
220*68*38.8mm (L*W*H)
|
PACKING
|
1.15Kg; 12pcs/14.4Kg/0.76CUFT
|
MODEL
|
HLG-150H-30
|
HLG-150H-36
|
HLG-150H-42
|
HLG-150H-48
|
HLG-150H-54
|
OUTPUT
|
DC VOLTAGE
|
30V
|
36V
|
42V
|
48V
|
54V
|
C&C REGION
|
15 ~ 30V
|
18 ~ 36V
|
21 ~ 42V
|
24 ~ 48V
|
27 ~ 54V
|
RATED CURRENT
|
5A
|
4.2A
|
3.6A
|
3.2A
|
2.8A
|
RATED POWER
|
150W
|
151.2W
|
151.2W
|
153.6W
|
151.2W
|
RIPPLE & NOISE
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
VOLTAGE ADJ.RANGE
|
27 ~ 33V
|
33 ~ 40V
|
38 ~ 46V
|
43 ~ 53V
|
49 ~ 58V
|
CURRENT ADJ.RANGE
|
Can be adjusted by internal potential meter .or through output cable
|
3 ~ 5A
|
2.5 ~ 4.2A
|
2.16~3.6A
|
1.92~3.2A
|
1.68~2.8A
|
VOLTAGE TOLERANCE
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
LINE REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
LOAD REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
SETUP, RISE TIME
|
2500ms, 50ms at full load 230VAC / 115VAC ; B type 2500ms, 200ms at 95% load 230VAC / 115VAC
|
HOLD UP TIME
|
16ms at full load 230VAC / 115VAC
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 305VAC 127 ~ 431VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
POWER FACTOR
|
PF 0.95/230VAC PF 0.98/115VAC at full load and rated output voltage PF 0.9 at 60 ~ 100% load
|
EFFICIENCY
|
93.5%
|
93.5%
|
94%
|
94%
|
94%
|
AC CURRENT
|
1.7A / 115VAC 0.75A / 230VAC 0.7A / 277VAC
|
INRUSH CURRENT
|
COLD START 75A/230VAC
|
LEAKAGE CURRENT
|
<0.75mA / 277VAC m
|