Features:
* Universal AC input / Full range
* Built-in active PFC function
* Protections: Short circuit / Overload / Over voltage / Over temperature
* Cooling by free air convection
* OCP point adjustable through output cable .or internal potential meter
* Suitable for LED lighting and moving sign applications IP67 / IP65 design for indoor .or outdoor installations Compliance to worldwide
* safety regulations for lighting
* Suitable for dry / damp / wet locations
* 5 years warranty
Specifications:
MODEL
|
HLG-240-12
|
HLG-240-15
|
HLG-240-20
|
HLG-240-24
|
OUTPUT
|
DC VOLTAGE
|
12V
|
15V
|
20V
|
24V
|
C&C REGION
|
6 ~12V
|
7.5 ~ 15V
|
10 ~ 20V
|
12 ~ 24V
|
RATED CURRENT
|
16A
|
15A
|
12A
|
10A
|
RATED POWER
|
192W
|
225W
|
240W
|
240W
|
RIPPLE & NOISE
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
VOLTAGE ADJ.
|
11.2~12.8V
|
14 ~ 16V
|
18.6~21.4V
|
22.4~25.6V
|
CURRENT ADJ.
|
Can be adjusted by internal potential meter .or through output cable
|
8 ~ 16A
|
7.5 ~ 15A
|
6 ~ 12A
|
5 ~ 10A
|
VOLTAGE TOLERANCE
|
2.5%
|
2.0%
|
1.0%
|
1.0%
|
LINE REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
LOAD REGULATION
|
2.0%
|
1.5%
|
1.0%
|
0.5%
|
SETUP RISE TIME
|
2500ms, 80ms at full load 230VAC /115VAC
|
HOLD UP TIME
|
15ms at full load 230VAC / 115VAC
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 264VAC 127 ~ 373VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
POWER FACTOR
|
PF 0.95/230VAC PF 0.98/115VAC at full load and rated output voltage PF 0.9 at 65 ~ 100% load
|
EFFICIENCY
|
90%
|
90%
|
92%
|
93%
|
AC CURRENT
|
4A / 115VAC 2A / 230VAC
|
INRUSH CURRENT
|
COLD START 75A/230VAC
|
LEAKAGE CURRENT
|
<0.75mA / 240VAC m
|
OTHERS
|
MTBF
|
207.9Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
244.2*68*38.8mm (L*W*H)(HLG-240-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240-C)
|
PACKING
|
1.3Kg; 12pcs/16.6Kg/0.74CUFT(HLG-240-Blank/A/B) 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
|
MODEL
|
HLG-240-30
|
HLG-240-36
|
HLG-240-42
|
HLG-240-48
|
HLG-240-54
|
OUTPUT
|
DC VOLTAGE
|
30V
|
36V
|
42V
|
48V
|
54V
|
C&C REGION
|
15 ~ 30V
|
18 ~ 36V
|
21 ~ 42V
|
24 ~ 48V
|
27 ~ 54V
|
RATED CURRENT
|
8A
|
6.7A
|
5.72A
|
5A
|
4.45A
|
RATED POWER
|
240W
|
241.2W
|
240.2W
|
240W
|
240.3W
|
RIPPLE & NOISE
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
VOLTAGE ADJ.RANGE
|
28 ~ 32V
|
33.5~38.5V
|
39 ~ 45V
|
44.8~51.2V
|
50 ~ 57V
|
CURRENT ADJ.
|
Can be adjusted by internal potential meter .or through output cable
|
4 ~ 8A
|
3.3 ~ 6.7A
|
2.86~5.72A
|
2.5 ~ 5A
|
2.23~4.45A
|
VOLTAGE TOLERANCE
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
LINE REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
LOAD REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
SETUP RISE TIME
|
2500ms, 80ms at full load 230VAC /115VAC
|
HOLD UP TIME
|
15ms at full load 230VAC / 115VAC
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 264VAC 127 ~ 373VDC
|
FREQUENCY
|
47 ~ 63Hz
|
POWER FACTOR
|
PF 0.95/230VAC PF 0.98/115VAC at full load and rated output voltage PF 0.9 at 65 ~ 100% load
|
EFFICIENCY
|
93%
|
93.5%
|
94%
|
94%
|
94%
|
AC CURRENT
|
4A / 115VAC 2A / 230VAC
|
INRUSH CURRENT
|
COLD START 75A/230VAC
|
LEAKAGE CURRENT
|
<0.75mA / 240VAC m
|
OTHERS
|
MTBF
|
207.9Khrs min. MIL-HDBK-217F
|
DIMENSION
|
244.2*68*38.8mm (L*W*H)(HLG-240-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240-C)
|
PACKING
|
1.3Kg; 12pcs/16.6Kg/0.74CUFT(HLG-240-Blank/A/B) 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
|