Features: * Universal AC input / Full range (up to 305VAC)
* Built-in active PFC function
* Protections: Short circuit / Overload / Over voltage / Over temperature
* Cooling by free air convection
* OCP point adjustable through output cable .or internal potential meter
* IP67 / IP65 design for indoor .or outdoor installations
* Three in one dimming function (1~10Vdc .or PWM signal .or resistance)
* Suitable for LED lighting and moving sign applications
* Compliance to worldwide safety regulations for lighting
* Suitable for dry / damp / wet location .or outdoor application
* 5 years warranty
Specifications:
MODEL
HLG-40H-12
HLG-40H-15
HLG-40H-20
HLG-40H-24
HLG-40H-30
HLG-40H-36
HLG-40H-42
HLG-40H-48
HLG-40H-54
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
30V
36V
42V
48V
54V
C&C REGION
7.2 ~12V
9 ~ 15V
12 ~ 20V
14.4 ~ 24V
18 ~ 30V
21.6~ 36V
25.2~ 42V
28.8~ 48V
32.4~ 54V
RATED CURRENT
3.33A
2.67A
2A
1.67A
1.34A
1.12A
0.96A
0.84A
0.75A
RATED POWER
39.96W
40.05W
40W
40.08W
40.2W
40.32W
40.32W
40.32W
40.5W
RIPPLE & NOISE
150mVp-p
150mVp-p
150mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
300mVp-p
300mVp-p
VOLTAGE ADJ.
10.8~ 13.5V
13.5~ 17V
17 ~ 22V
22 ~ 27V
27 ~ 33V
33 ~ 40V
38 ~ 46V
43 ~ 53V
49 ~ 58V
CURRENT ADJ.
Can be adjusted by internal potential meter .or through output cable
2 ~ 3.33A
1.6 ~ 2.67A
1.2 ~ 2A
1~ 1.67A
0.8~ 1.34A
0.67~ 1.12A
0.58~ 0.96A
0.5~ 0.84A
0.45~ 0.75A
VOLTAGE TOLERANCE
2.5%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1500ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load
HOLD UP TIME
16ms at full load 230VAC /115VAC
INPUT
VOLTAGE RANGE
90 ~ 305VAC 127 ~ 431VDC
FREQUENCY
47 ~ 63Hz
POWER FACTOR
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)