Features: * Universal AC input / Full range (up to 305VAC)
* Built-in active PFC function
* High efficiency up to 91%
* Protections: Short circuit / Overload / Over voltage / Over temperature
* Cooling by free air convection
* Fully isolated plastic case
* Fully encapsulated with IP67 level (Note.6)
* Class II power unit, no FG
* Suitable for LED lighting and moving sign applications
* Compliance to worldwide safety regulations for lighting
* Suitable for dry / damp / wet locations
* 3 years warranty
Specifications
MODEL
LPF-90D-15
LPF-90D-20
LPF-90D-24
LPF-90D-30
LPF-90D-36
LPF-90D-42
LPF-90D-48
LPF-90D-54
OUTPUT
DC VOLTAGE
15V
20V
24V
30V
36V
42V
48V
54V
CONSTANT CURRENT REGION
9 ~ 15V
12 ~ 20V
14.4~ 24V
18 ~ 30V
21.6~ 36V
25.2~ 42V
28.8~ 48V
32.4~ 54V
RATED CURRENT
5A
4.5A
3.75A
3A
2.5A
2.15A
1.88A
1.67A
RATED POWER
90W
90W
90W
90W
90W
90.3W
90.24W
90.18W
RIPPLE & NOISE
150mVp-p
150mVp-p
150mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
VOLTAGE TOLERANCE N
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
2000ms, 200ms at 95% load 230VAC / 115VAC
HOLD UP TIME
16ms/230VAC 16ms/115VAC at full load
INPUT
VOLTAGE RANGE
90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF>0.97/115VAC, PF>0.96/230VAC, PF>0.95/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
89%
89.5%
90%
90.5%
90.5%
90.5%
90.5%
90.5%
AC CURRENT
0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC
INRUSH CURRENT
COLD START 75A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
PROTECTION
OVERCURRENT
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE
18 ~ 21V
23 ~ 27V
28 ~ 34V
34 ~ 38V
41 ~ 46V
47 ~ 53V
54 ~ 60V
59 ~ 65V
Protection type : Shut down o/p voltage with auto-recovery .or re-power on to recovery
OVER TEMPERATURE
105oC 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
WORKING TEMP.
-40 ~ +70oC (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +80oC , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/oC (0 ~ 50oC )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes