MODEL
|
LPF-90D-15
|
LPF-90D-20
|
LPF-90D-24
|
LPF-90D-30
|
LPF-90D-36
|
LPF-90D-42
|
LPF-90D-48
|
LPF-90D-54
|
OUTPUT
|
DC VOLTAGE
|
15V
|
20V
|
24V
|
30V
|
36V
|
42V
|
48V
|
54V
|
CONSTANT CURRENT REGION Note.4
|
9 ~ 15V
|
12 ~ 20V
|
14.4~ 24V
|
18 ~ 30V
|
21.6~ 36V
|
25.2~ 42V
|
28.8~ 48V
|
32.4~ 54V
|
RATED CURRENT
|
5A
|
4.5A
|
3.75A
|
3A
|
2.5A
|
2.15A
|
1.88A
|
1.67A
|
RATED POWER
|
75W
|
90W
|
90W
|
90W
|
90W
|
90.3W
|
90.24W
|
90.18W
|
RIPPLE & NOISE (max.) Note.2
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
VOLTAGE TOLERANCE Note.3
|
4.0%
|
4.0%
|
4.0%
|
4.0%
|
4.0%
|
4.0%
|
4.0%
|
4.0%
|
LINE REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
LOAD REGULATION
|
1.5%
|
1.0%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
SETUP, RISE TIME
|
2000ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load
|
HOLD UP TIME (Typ.)
|
16ms/230VAC 16ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 305VAC 127 ~ 431VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
POWER FACTOR
|
PF>0.97/115VAC, PF>0.96/230VAC, PF>0.95/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
|
EFFICIENCY (Typ.)
|
89%
|
90%
|
90.5%
|
91%
|
91%
|
91%
|
91%
|
91%
|
AC CURRENT (Typ.)
|
0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC
|
INRUSH CURRENT (Typ.)
|
COLD START 75A/230VAC
|
LEAKAGE CURRENT
|
<0.75mA / 277VAC
|
PROTECTION
|
OVERCURRENT
|
95 ~ 108%
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed
|
SHORT CIRCUIT
|
Hiccup mode, recovers automatically after fault condition is removed.
|
OVER VOLTAGE
|
18 ~ 21V
|
23 ~ 27V
|
28 ~ 34V
|
34 ~ 38V
|
41 ~ 46V
|
47 ~ 53V
|
54 ~ 60V
|
59 ~ 65V
|
Protection type : Shut down o/p voltage with auto-recovery .or re-power on to recovery
|
OVER TEMPERATURE
|
90oC 10 (RTH2)
|
Protection type : Shut down o/p voltage, re-power on to recover
|
ENVIRONMENT
|
WORKING TEMP.
|
-40 ~ +70oC (Refer to "Derating Curve")
|
WORKING HUMIDITY
|
20 ~ 95% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-40 ~ +80oC , 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.03%/ oC (0 ~ 50oC )
|
VIBRATION
|
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
|
SAFETY &EMC(Note 4)
|
SAFETY STANDARDS
|
UL8750, EN61347-1, EN61347-2-13 independent, IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
|
WITHSTAND VOLTAGE
|
I/P-O/P:3.75KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55015, Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2,CLASS C( 60% load),EN61000-3-3
|
EMS
IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A
|
OTHERS
|
MTBF
|
301.6Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
161*61*36mm (L*W*H)
|
PACKING
|
0.7Kg; 20pcs/15Kg/0.73CUFT
|