MODEL
|
LPF-60-12
|
LPF-60-15
|
LPF-60-20
|
LPF-60-24
|
LPF-60-30
|
LPF-60-36
|
LPF-60-42
|
LPF-60-48
|
LPF-60-54
|
OUTPUT
|
DC VOLTAGE
|
12V
|
15V
|
20V
|
24V
|
30V
|
36V
|
42V
|
48V
|
54V
|
CONSTANT CURRENT REGION Note.4
|
7.2 ~12V
|
9 ~ 15V
|
12 ~ 20V
|
14.4~ 24V
|
18 ~ 30V
|
21.6~ 36V
|
25.2~ 42V
|
28.8~ 48V
|
32.4~ 54V
|
RATED CURRENT
|
5A
|
4A
|
3A
|
2.5A
|
2A
|
1.67A
|
1.43A
|
1.25A
|
1.12A
|
RATED POWER
|
60W
|
60W
|
60W
|
60W
|
60W
|
60.12W
|
60.06W
|
60W
|
60.48W
|
RIPPLE & NOISE (max.)? Note.2
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
200mVp-p
|
250mVp-p
|
250mVp-p
|
250mVp-p
|
350mVp-p
|
VOLTAGE TOLERANCE?? Note.3
|
4.0%
|
4.0%
|
4.0%
|
4.0%
|
4.0%
|
4.0%
|
4.0%
|
4.0%
|
4.0%
|
LINE REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
LOAD REGULATION
|
2.0%
|
2.0%
|
1.5%
|
1.0%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
SETUP, RISE TIME
|
1000ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC
|
HOLD UP TIME (Typ.)
|
16ms at full load 230VAC /115VAC
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 305VAC 127 ~ 431VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
POWER FACTOR
|
PF 0.95/230VAC PF 0.98/115VAC at full load and rated output voltage PF 0.9 at 60 ~ 100% load
|
EFFICIENCY (Typ.)
|
86%
|
87%
|
88%
|
89%
|
90%
|
90%
|
91%
|
91%
|
91%
|
AC CURRENT (Typ.)
|
0.8A / 115VAC 0.4A / 230VAC
|
INRUSH CURRENT (Typ.)
|
COLD START 75A/230VAC
|
LEAKAGE CURRENT
|
<0.75mA / 240VAC
|
PROTECTION
|
OVERCURRENT
|
95 ~ 108%
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed
|
SHORT CIRCUIT
|
Hiccup mode, recovers automatically after fault condition is removed.
|
OVER VOLTAGE
|
14 ~ 16V
|
17.5 ~ 21V
|
23 ~ 27V
|
28 ~ 35V
|
34 ~ 38V
|
41 ~ 49V
|
46 ~ 54V
|
54 ~ 63V
|
59 ~ 65V
|
Protection type : Shut down o/p voltage with auto-recovery .or re-power on to recovery
|
OVER TEMPERATURE
|
105? 10 (RTH2)
|
Protection type : Shut down o/p voltage, re-power on to recover
|
ENVIRONMENT
|
WORKING TEMP.
|
-30 ~ +50 @ full load ; +70 @ 60% load (Refer to derating curve)? ; -40 can power on
|
WORKING HUMIDITY
|
20 ~ 95% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-40 ~ +80 , 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.03%/ (0 ~ 50 )
|
VIBRATION
|
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
|
SAFETY &EMC(Note 4)
|
SAFETY STANDARDS
|
UL8750, EN61347-1, EN61347-2-13 independent, IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55015, Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2,CLASS C( 60% load),EN61000-3-3
|
EMS
IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level, criteria A
|
OTHERS
|
MTBF
|
Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
162.5*42.5*32mm (L*W*H)
|
PACKING
|
Kg; 32pcs/ Kg/0.56CUFT
|