Hangzhou Showland Power Co.,Ltd

RSP-2400

RSP-2400,
RSP-2400
  • Product:
    RSP-2400

  • Model Number:


  • Description:
     


    Learn more about products detailed description, pricing and service, Please send mail to us!

    sales@showlandpower.com
2400W Single Output Power Supply RSP-24 00 series

Features:
*  AC input 180 ~ 264VAC
AC input active surge current limiting
High efficiency up to 91%
Built-in active PFC function,PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature/ Fan alarm
Forced air cooling by built-in DC with fan speed control function
Output voltage can be trimmed between 20~110% of the rated output voltage
High power density 12.5W/inch3
Current sharing up to 3 units
Alarm signal output (relay contact and TTL signal) Built-in 12V/0.1A auxiliary output for remote control Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty

Specifications: 

MODEL

RSP-2400-12 

RSP-2400-24

RSP-2400-48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

12V

24V

48V

CURRENT RANGE

0 ~ 166.7A 

0 ~ 100A     

0 ~ 50A

RATED CURRENT

166.7A

100A

50A

RATED POWER

2000.4W

2400W

2400W

RIPPLE & NOISE

150mVp-p 

150mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

10.8 ~ 13.2V  

22 ~ 28V   

43 ~ 56V

VOLTAGE TOLERANCE

1.0%

1.0%

1.0%

LINE REGULATION

0.5%

LOAD REGULATION

0.5%

0.5%

0.5%

SETUP, RISE TIME NOTE.5 

1000ms, 80ms at full load

HOLD UP TIME (TYP)

12ms at full load

 

 

 

 

INPUT

VOLTAGE RANGE

180 ~ 264VAC  254 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

0.95/230VAC at full load

EFFICIENCY (Typ.)

87%

90%

91.5%

AC CURRENT (Typ.)

15.5A/180VAC  12A/230VAC

INRUSH CURRENT (Typ.)

60A/230VAC

LEAKAGE CURRENT

<2.0mA / 240VAC

 

PROTECTION

OVER LOAD

100 ~ 112% rated output power

User adjustable continuous constant current limiting .or constant current limiting with delay shutdown after 5 seconds, re-power on to recover

OVER VOLTAGE

13.8 ~ 16.8V 

28.8 ~ 33.6V     

57.6 ~ 67.2V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

95 oC  5  (12V), 100oC 5 (24V,48V) (TSW1: detect on heatsink of power transistor)

95oC   5  (12V), 85oC 5 (24V), 80 5 (48V)  (TSW2 : detect on heatsink of o/p diode)

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

 

 

 

 

 

FUNCTION

AUXILIARY POWER

12V@0.1A(Only for Remote ON/OFF control)

REMOTE CONTROL

Please refer to function manual

CURRENT SHARING

Please refer to function manual

OUTPUT VOLTAGE TRIM

2.4 ~ 13.2V  

4.8 ~ 28V

9.6 ~ 56V

CURRENT SHARING

Please see the Function Manual

 

 

 

 

ENVIRONMENT

WORKING TEMP.

-20 ~ +70oC (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85oC , 10 ~ 95% RH  non-condensing

TEMP. COEFFICIENT

0.05%/oC (0 ~ 50oC ) 

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for  60min. each along X, Y, Z axes

 

 

 

 

 

SAFETY &EMC

SAFETY STANDARDS

UL60950-1, TUV EN60950-1 approved

WITHSTAND VOLTAGE  

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH

EMI CONDUCTION & RADIATION

Compliance to EN55022 (CISPR22)

HARMONIC CURRENT

Compliance to EN61000-3-2,-3

EMS IMMUNITY    

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A

 

OTHERS

MTBF

106.7K hrs min. MIL-HDBK-217F (25 )

DIMENSION

278*177.8*63.5mm (L*W*H)

PACKING  

3.3Kg; 4pcs/14.2Kg/1.89CUFT

 

NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature.

2Ripple & noisarmeasurea20MHobandwidtbusing a 12twistepair-wirterminatewith a 0.1uf & 47uparallecapacitor.

3Tolerance : includeseutolerancelinregulatioanloaregulation.

4Thpowesuppliconsidered a componenwhicwilbinstalleinto a finaequipmentThfinaequipmenmusbre-confirmethaistilmeetEMdirectives.


Related Product