MODEL
|
S-100F-5
|
S-100F-7.5
|
S-100F-12
|
S-100F-15
|
S-100F-24
|
S-100F-48
|
OUTPUT
|
DC VOLTAGE
|
5V
|
7.5V
|
12V
|
15V
|
24V
|
48V
|
RATED CURRENT
|
20A
|
13.5A
|
8.5A
|
6.7A
|
4.5A
|
2.2A
|
CURRENT RANGE
|
0 ~ 20A
|
0 ~ 13.5A
|
0 ~ 8.5A
|
0 ~ 6.7A
|
0 ~ 4.5A
|
0 ~ 2.2A
|
RATED POWER
|
100W
|
101W
|
102W
|
100.5W
|
108W
|
105.6W
|
RIPPLE & NOISE
|
100mVp-p
|
125mVp-p
|
125mVp-p
|
|
150mVp-p
|
150mVp-p
|
VOLTAGE ADJ. RANGE
|
4.5 ~ 5.5V
|
6.75 ~ 8.25V
|
10.8 ~ 13.2V
|
13.5 ~ 16.5V
|
21.6 ~ 26.4V
|
43.2 ~ 52.8V
|
VOLTAGE
TOLERANCE
|
2.0%
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
1.0%
|
LINE REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
LOAD REGULATION
|
1.0%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
SETUP, RISE TIME
|
1000ms, 30ms at full load
|
HOLD UP TIME
|
20ms at full load
|
INPUT
|
VOLTAGE RANGE
|
88 ~ 132VAC/176 ~ 264VAC selected by jumper .or switch 248 ~ 370VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
EFFICIENCY
|
76%
|
78%
|
80%
|
81%
|
83%
|
84%
|
AC CURRENT (Typ.)
|
3.15A/115VAC 1.5A/230VAC
|
INRUSH CURRENT
|
COLD START 20A/115VAC 40A/230VAC
|
LEAKAGE CURRENT
|
<1mA / 240VAC
|
PROTECTION
|
OVERLOAD
|
105 ~ 150% rated output power
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
OVER VOLTAGE
|
5.75 ~ 6.75V
|
8.63 ~ 10.13V
|
13.8 ~ 16.2V
|
17.25 ~ 20.25V
|
27.6 ~ 32.4V
|
55.2 ~ 64.8V
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
ENVIRONMENT
|
WORKING TEMP.
|
-10 ~ +60 (Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 90% RH non-condensing
|
STORAGE TEMP HUMIDITY
|
-20 ~ +85 , 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.03%/ (0 ~ 50
|
VIBRATION
|
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
|
SAFETY &EMC
|
SAFETY STANDARDS
|
CSA60950-1 (for 24V only), UL1012, UL60950-1, TUV EN60950-1, CCC GB4943 approved
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55022 (CISPR22) Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2,-3
|
EMS
IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
|
OTHERS
|
MTBF
|
314.9K hrs min.&nnbsp;MIL-HDBK-217F (25 )
|
DIMENSION
|
199*98*38mm (L*W*H)
|
PACKING
|
0.65Kg; 20pcs/14.2Kg/0.8CUFT
|
NOTE
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25? of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
|