60W Isolated Quad Output Switching Power Supply IQ-60D / IQ-60F
Features:
* Isolated output & GND for CH1,CH2 & CH3,CH4
* Universal AC input/Full range
* Protections:Short circuit/Over load/Over voltage
* LED indicator for power on
* 100% full load burn-in test
* Fixed switching frequency at 67KHz
* 2 years warranty
Specifications:
MODEL
IQ-60D
OUTPUT
OUTPUT NUMBER
CH1
CH2
CH3
CH4
DC VOLTAGE
5V
12V
-12V
24V
CURRENT RANGE
0.5 ~ 3A
0.1 ~ 1A
0.1 ~ 1A
0.2 ~ 2A
RATED CURRENT
3A
0.5A
0.5A
1.3A
RATED POWER
58.2W
RIPPLE & NOISE (max.) Note.2
80mVp-p
120mVp-p
120mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
CH1 : 4.75 ~ 5.5V
VOLTAGE TOLERANCE
NOTE.3
3.0%
8.0%
8.0%
8.0%
LINE REGULATION
1.0%
2.0%
2.0%
2.0%
LOAD REGULATION
2.0%
5.0%
5.0%
5.0%
SETUP, RISE TIME NOTE.5
300ms, 20ms/230VAC 800ms, 20ms/115VAC at full load
HOLD TIME (Typ.)
80ms/230VAC 18ms/115VAC at full load
INPUT
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
AC CURRENT (Typ.)
1.8A/115VAC 0.9A/230VAC
INRUSH CURRENT (Typ.)
COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
PROTECTION
OVER LOAD
70 ~ 90W rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
5V : 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
WORKING TEMP.
-10 ~ +60oC (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-20 ~ +85oC , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/oC (0 ~ 50oC) on +5V output
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &EMC(Note 4)
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 Approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, Light industry level, criteria A
OTHERS
MTBF
313K hrs min. MIL-HDBK-217F
DIMENSION
159*97*38mm (L*W*H)
PACKING
0.55Kg; 24pcs/14.2Kg/0.75CUFT
MODEL
IQ-60F
OUTPUT
OUTPUT NUMBER
CH1
CH2
CH3
CH4
DC VOLTAGE
5V
15V
-15V
24V
CURRENT RANGE
0.5 ~ 3A
0.1 ~ 1A
0.1 ~ 1A
0.2 ~ 2A
RATED CURRENT
3A
0.5A
0.5A
1.25A
RATED POWER
60W
RIPPLE & NOISE (max.) Note.2
80mVp-p
150mVp-p
150mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
CH1 : 4.75 ~ 5.5V
VOLTAGE TOLERANCE
NOTE.3
3.0%
8.0%
8.0%
8.0%
LINE REGULATION
1.0%
2.0%
2.0%
2.0%
LOAD REGULATION
2.0%
5.0%
5.0%
5.0%
SETUP, RISE TIME NOTE.5
300ms, 20ms/230VAC 800ms, 20ms/115VAC at full load
HOLD TIME (Typ.)
80ms/230VAC 18ms/115VAC at full load
INPUT
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
AC CURRENT (Typ.)
1.8A/115VAC 0.9A/230VAC
INRUSH CURRENT (Typ.)
COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
PROTECTION
OVER LOAD
70 ~ 90W rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
5V : 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
WORKING TEMP.
-10 ~ +60oC (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-20 ~ +85oC , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/oC (0 ~ 50oC ) on +5V output
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &EMC(Note 4)
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 Approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, Light industry level, criteria A
OTHERS
MTBF
313K hrs min. MIL-HDBK-217F
DIMENSION
159*97*38mm (L*W*H)
PACKING
0.55Kg; 24pcs/14.2Kg/0.75CUFT
NOTE
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation
4. 5% Duty cycle maximum within every 1min. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets