500W Single Output with PFC Function USP-500 series

Features:
*  Universal AC input / Full range
*  Built in active PFC circuit compliance to EN61000-3-2
*  Protections: Short circuit / Overload / Over voltage / Over temperature
*  Free air convection for 400W and 500W with 23.5CFM forced air
*  High power density 6.2w/in3
*  AC input active surge current limiting
*  U-bracket low profile:41mm
*  Current sharing(1+1) for 24V and 48V models (Optional)
*  Built-in remote ON-OFF control
*  Built-in remote sense function
*  Built in DC OK active signal
*  3 years warranty

Specifications:

MODEL

USP-150-5

USP-150-12

USP-150-15

USP-150-24

USP-150-48

 

 

 

 

 

 

 

 

 

 

 OUTPUT

DC VOLTAGE

5V

12V

15V

24V

48V

CURRENT RANGE (convection)

0 ~ 60A 

0 ~ 33A 

0 ~ 27A   

0 ~ 17A  

0 ~ 8.5A

CURRENT RANGE (23.5CFM FAN)

0 ~ 80A 

0 ~ 42A

0 ~ 33.5A

0 ~ 21A  

0 ~ 10.5A

RATED CURRENT

80A

42A

33.5A

21A

10.5A

RATED POWER (convection)

300W

396W

405W

408W

408W

RATED POWER (23.5CFM FAN)

400W

504W

502.5W

504W

504W

RIPPLE & NOISE (max.)  Note.2

80mVp-p  

100mVp-p

100mVp-p

150mVp-p

150mVp-p

VOLTAGE ADJ. RANGE

4.5 ~ 5.5V

10.8~13.2V

13.5~16.5V

21.6 ~ 27V

43.2~52.8V

VOLTAGE TOLERANCE

2.0%                                                      

LINE REGULATION

0.5%

LOAD REGULATION

2.0%

1.0%  

SETUP, RISE TIME NOTE.5 

1500ms, 80ms/230VAC   3100ms, 80ms/115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC    20ms/115VAC at full load

 

 

 

 

 

INPUT

VOLTAGE RANGE

90 ~ 264VAC  127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

0.95/230VAC    0.98/115VAC at full load

EFFICIENCY (Typ.)

85%

90%

90%

89%

90%

AC CURRENT (Typ.)

6A/115VAC    2.6A/230VAC

INRUSH CURRENT (Typ.)

30A/115VAC    50A/230VAC

LEAKAGE CURRENT

<2mA / 240VAC

 

 

 

 

PROTECTION

OVER LOAD

105 ~ 130% rated output power

Protection type : Constant current limiting, unit will shut down after 3 sec. ,re-power on to recover

OVER VOLTAGE

5.7 ~ 7V 

13.5 ~ 16V

17 ~ 21V

27.8~32.4V

53 ~ 64.8V

Protection type : Shut down o/p voltage, re-power to recover

OVER TEMPERATURE

85?   �5 (TSW1 : detect on heatsink of o/p diode)

95?   �5(5V),100 (12V,15V,24V,48V) (TSW2 : detect on heatsink of power transistor)

Protection type : Shut down o/p voltage with auto-recovery

REMOTE ON/OFF CONTROL  

RC+/RC-: 0~0.8V power on ; 4~10V power off

DC-OK SIGNAL

PSU turn on : 3.3V ~ 5.6V ; PSU turn off: 0 ~ 1V

 

 

 ENVIRONMENT

WORKING TEMP.

-20 ~ +70oC (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85oC , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/oC (0 ~ 60oC ) 

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for  60min. each along X, Y, Z axes

 

 

 

 

 

 

 

SAFETY &EMC

SAFETY STANDARDS

UL60950-1, TUV EN60950-1 approved

WITHSTAND VOLTAGE  

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH

EMI CONDUCTION & RADIATION

Compliance to EN55022 (CISPR22) Class B

HARMONIC CURRENT

Compliance to EN61000-3-2,EN61000-3-3

EMS 

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level (surge 4KV),  criteria A

 

OTHERS

MTBF

254*127*41mm (L*W*H)

DIMENSION

1.6Kg; 6pcs/10.6Kg/0.67CUFT

PACKING  

0.48kg;  24PCS/12.5kg/0.61CUFT

 

 

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltages. Please check the static characteristics for more details.

5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets

EMC directives.

 


Related Product