Hangzhou Showland Power Co.,Ltd

RPS-160

RPS-160,
RPS-160
  • Product:
    RPS-160

  • Model Number:


  • Description:
     


    Learn more about products detailed description, pricing and service, Please send mail to us!

    sales@showlandpower.com
160W Single Output Medical Type RPS-160 series

Features:
*  Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
5"x3" compact size
Free air convection for 110W and 160W with 20.5 CFM forced air
With power good and fail signal output
Built-in remote sense function for 5~15V
No load power consumption under 0.75W by PS-ON control (G model) Standby 5V@0.8A with fan, @0.6A without fan (G model)
3 years warranty

Specifications:

MODEL

RPS-160-5

RPS-160-12

RPS-160-15  

RPS-160-24

RPS-160-48

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

48V

RATED CURRENT

30A

12.9A

10.3A

6.5A

3.25A

CURRENT RANGE

0 ~ 20A 

0 ~ 9.1A  

0 ~ 7.3A

0 ~ 4.6A

0 ~ 2.3A

CURRENT RANGE 

0 ~ 30A 

0 ~ 12.9A

0 ~ 10.3A

0 ~ 6.5A  

0 ~ 3.25A

RATED POWER 

103W

112.2W

112.5W

113.4W

113.4W

PEAK LOAD

155W

159.8W

159.5W

161W

161W

RIPPLE & NOISE 

100mVp-p 

100mVp-p

120mVp-p

150mVp-p

250mVp-p

VOLTAGE ADJ. 

CH1:4.5 ~ 5.5V 

CH1:10.8 ~ 13.2V  

CH1:13.5 ~ 16.5V

CH1:22 ~ 27V  

CH1:43.2 ~ 52.8V

VOLTAGE TOLERANCE   

4.0%

3.0%

3.0%

2.0%

2.0%

LINE REGULATION

0.5%

0.5%

0.5%

0.5%

0.5%

LOAD REGULATION 

1.0%

1.0%

1.0%

1.0%

1.0%

SETUP, RISE TIME  

1200ms, 30ms/230VAC     2500ms, 30ms/115VAC at full load

HOLD UP TIME

16ms/230VAC/115VAC at full load

 

 

 

 

INPUT

VOLTAGE RANGE

90 ~ 264VAC   127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR 

PF>0.93/230VAC    PF>0.98/115VAC at full load

EFFICIENCY 

85%

87%

87%

87%

88%

AC CURRENT 

2A/115VAC     1.1A/230VAC

INRUSH CURRENT

COLD START 35A/115VAC     70A/230VAC

LEAKAGE CURRENT

Earth leakage current <300uA / 264VAC, patient leakage current <100uA/264VAC

 

PROTECTION

OVER LOAD

105 ~ 135% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER TEMP

95  (5V),90 (12V,15V,24V,48V) (TSW2 : detect on heatsink of power transistor)

Protection type : (TSW1)Shut down o/p voltage, recovers automatically after temperature goes down

OVER VOLTAGE

5.75 ~ 6.75V  

13.8 ~ 16.2V

17.25 ~ 20.25V

27.6 ~ 32.4V

55.2 ~ 64.8V

Protection type : Shut down o/p voltage, re-power to recover

FUNCTION

5V STANDBY

5VSB : 5V@0.6A without fan, 0.8A with fan 20.5CFM ; tolerance 2%, ripple : 50mVp-p(max.)

INPUT SIGNAL

Power on: PS-ON = "Hi" .or " > 2 ~ 5V" ; Power off: PS-ON = "Low" .or " < 0 ~ 0.5V"

POWER GOOD /FAIL

500ms>PG>10ms      PF>1ms

REMOTE SENSE

5 ~ 15V

 

 

 

ENVIRONMENT

WORKING TEMP.

-20 ~ +70oC (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP HUMIDITY

-40 ~ +85oC , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/oC  (0 ~ 50oC ) 

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes