60W Single Output Medical Type RPS-60 series
Features: * 4"x2" miniature size
* Universal AC input/Full range
* Low leakage current<200uA
* Protections: Short circuit / Overload / Over voltage
* Cooling by free air convection
* UL60601-1/IEC60601-1/EN60601-1 medical safety approved
* UL60950-1/IEC60950-1/EN60950-1 ITE safety approved
* No load power consumption<0.75W Fixed switch frequency at 100KHz
* 3 years warranty Specifications: MODEL RPS-60-3.3 RPS-60-5 RPS-60-12 RPS-60-15 RPS-60-24 RPS-60-48 OUTPUT DC VOLTAGE 3.3V 5V 12V 15V 24V 48V RATED CURRENT 10A 10A 5A 4A 2.5A 1.25A CURRENT RANGE 0 ~ 11A 0 ~ 11A 0 ~ 5.5A 0 ~ 4.4A 0 ~ 2.75A 0 ~ 1.375A RATED POWER 33W 50W 60W 60W 60W 60W PEAK LOAD 10sec 36.3W 55W 66W 66W 66W 66W RIPPLE & NOISE 80mVp-p 80mVp-p 120mVp-p 150mVp-p 240mVp-p 300mVp-p VOLTAGE ADJ. RANGE 3.1 ~ 3.6V 4.75 ~ 5.5V 11.4 ~ 13.2V 13.5 ~ 16.5V 22.8 ~ 27.6V 45.6 ~ 52.8V VOLTAGE TOLERANCE 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load HOLD UP TIME 50ms/230VAC 13ms/115VAC at full load INPUT VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC FREQUENCY 47 ~ 63Hz EFFICIENCY 74% 79% 83% 84% 85% 86% AC CURRENT 1.8A/115VAC 1 A/230VAC INRUSH CURRENT COLD START 60A/230VAC 30A/115VAC LEAKAGE CURRENT For earth <200uA / 264VAC, For patient <100uA/264VAC PROTECTION OVER LOAD 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 3.8 ~ 5V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 28.4 ~ 32.4V 55.2 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover ENVIRONMENT WORKING TEMP. -20 ~ +70oC (Refer to output load derating curve) WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +85oC , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ oC (0 ~ 45oC ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY &EMC SAFETY STANDARDS UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved WITHSTAND VOLTAGE I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A MTBF 353.6Khrs min. MIL-HDBK-217F (25 ) DIMENSION 101.6*50.8*29mm (L*W*H) PACKING 0.15Kg; 96pcs/15.4Kg/0.89CUFT
Related Product
|