MODEL
|
USP-225-3.3
|
USP-225-5
|
USP-225-12
|
USP-225-15
|
USP-225-24
|
USP-225-48
|
OUTPUT
|
DC VOLTAGE
|
3.3V
|
5V
|
12V
|
15V
|
24V
|
48V
|
CURRENT RANGE
|
0 ~ 40A
|
0 ~ 40A
|
0~ 18.7A
|
0 ~ 15A
|
0 ~ 9.4A
|
0 ~ 4.7A
|
RATED CURRENT
|
40A
|
40A
|
18.7A
|
15A
|
9.4A
|
4.7A
|
RATED POWER
|
132W
|
200W
|
224.4W
|
225W
|
225.6W
|
225.6W
|
RIPPLE & NOISE (max.) Note.2
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
150mVp-p
|
250mVp-p
|
VOLTAGE ADJ. RANGE
|
2.97 ~ 3.6V
|
4.5 ~ 5.5V
|
10.8 ~ 13.2V
|
13.5 ~ 16.5V
|
21.6 ~ 26.4V
|
43.2 ~ 52.8V
|
VOLTAGE TOLERANCE
NOTE.3
|
2.0%
|
LINE REGULATION
|
0.5%
|
LOAD REGULATION
|
1.0%
|
SETUP, RISE TIME NOTE.5
|
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
|
HOLD UP TIME (Typ.)
|
22ms/230VAC 22ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 264VAC 127 ~ 370VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
POWER FACTOR (Typ.)
|
PF>0.93/230VAC PF>0.97/115VAC at full load
|
EFFICIENCY (Typ.)
|
72%
|
77%
|
83%
|
84%
|
85%
|
86%
|
AC CURRENT (Typ.)
|
115VAC
|
2.2A
|
3.3A
|
230VAC
|
1.1A
|
1.6A
|
INRUSH CURRENT (Typ.)
|
15A/115VAC 30A/230VAC
|
LEAKAGE CURRENT
|
<3.5mA / 240VAC
|
PROTECTION
|
OVER LOAD
|
105 ~ 150% rated output power
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed
|
OVER VOLTAGE
|
3.6 ~ 4.4V
|
5.5 ~ 7.4V
|
13.2 ~ 16.3V
|
16.5 ~ 20.2V
|
26.4 ~ 32.4V
|
52.8 ~ 64.8V
|
Protection type : Shut down o/p voltage, re-power on to recover
|
OVER TEMPERATURE
|
95? �5 (RTH2 : detect on heatsink of power transistor)
|
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
|
ENVIRONMENT
|
WORKING TEMP.
|
-20 ~ +65oC (Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-40 ~ +85oC , 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.03%/oC (0 ~ 50oC )
|
VIBRATION
|
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
SAFETY &EMC
|
SAFETY STANDARDS
|
UL60950-1, TUV EN60950-1 approved
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55022 (CISPR22) Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2,-3
|
EMS
IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
|
OTHERS
|
MTBF
|
220K hrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
202*101.5*38mm (L*W*H)
|
PACKING
|
0.85Kg; 16pcs/14.6Kg/0.76CUFT
|
NOTE
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
|