Features:
* Universal AC input / Full range (up to 295VAC)
* Protections: Short circuit / Overload / Over voltage / Over temperature
* Output voltage and constant current level adjustable
* Built-in active PFC function
* IP66 design for indoor .or outdoor installations
* Cooling by free air convection
* 100% full load burn-in test
* High reliability
* Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting Suitable for dry / damp / wet locations
* 3 years warranty
Specifications:
MODEL
|
CEN-100-20
|
CEN-100-24
|
CEN-100-30
|
CEN-100-36
|
CEN-100-42
|
CEN-100-48
|
CEN-100-54
|
OUTPUT
|
DC VOLTAGE
|
20V
|
24V
|
30V
|
36V
|
42V
|
48V
|
54V
|
C&C OPERATION VOLTAGE
|
13 ~ 20V
|
15.6 ~ 24V
|
19.5 ~ 30V
|
23.4 ~ 36V
|
27.3 ~ 42V
|
31.2 ~ 48V
|
35.1 ~ 54V
|
CURRENT RANGE
|
0 ~ 4.8A
|
0 ~ 4A
|
0 ~ 3.2A
|
0 ~ 2.65A
|
0 ~ 2.28A
|
0 ~ 2A
|
0 ~ 1.77A
|
RATED CURRENT
|
4.8A
|
4A
|
3.2A
|
2.65A
|
2.28A
|
2A
|
1.77A
|
RATED POWER
|
96W
|
96W
|
96W
|
95.4W
|
95.76W
|
96W
|
95.58W
|
RIPPLE & NOISE
|
2.0Vp-p
|
2.7Vp-p
|
3Vp-p
|
3.6Vp-p
|
4Vp-p
|
4.6Vp-p
|
5Vp-p
|
VOLTAGE ADJ. RANGE
|
17 ~ 22V
|
22 ~ 27V
|
27 ~ 33V
|
33 ~ 40V
|
37 ~ 46V
|
43 ~ 53V
|
49 ~ 58V
|
VOLTAGE ADJ. RANGE
|
3.12 ~ 4.8A
|
2.6 ~ 4A
|
2.08 ~ 3.2A
|
1.72 ~ 2.65A
|
1.48 ~ 2.28A
|
1.3 ~ 2A
|
1.15 ~ 1.77A
|
VOLTAGE TOLERANCE
|
10%
|
LINE REGULATION
|
3.0%
|
LOAD REGULATION
|
5.0%
|
SETUP, RISE TIME
|
3000ms / 230VAC 5000ms / 115VAC at full load
|
HOLD UP TIME (Typ.)
|
|
INPUT
|
VOLTAGE RANGE
|
Note.4 90 ~ 295VAC 127 ~ 417VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
POWER FACTOR
|
PF 0.9 at 65 ~ 100% load, 115VAC / 230VAC ; PF>0.97 / 115VAC PF>0.95 / 230VAC at full load
|
EFFICIENCY (Typ.)
|
88%
|
89%
|
90%
|
90%
|
90%
|
91%
|
91%
|
AC CURRENT (Typ.)
|
1.4A/115VAC 0.7A/230VAC
|
INRUSH CURRENT (Typ.)
|
60A/230VAC
|
LEAKAGE CURRENT
|
<0.75mA / 240VAC
|
OTHERS
|
MTBF
|
519.5Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
193*62.5*40.5mm (L*W*H)
|
PACKING
|
0.6Kg; 24pcs/15.4Kg/1.11CUFT
|