Features:
* Constant voltage design
* Universal AC input / Full range
* Fully encapsulated with IP67 level
* Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage Fully isolated plastic case
* Cooling by free air convection
* UL1310 Class 2 power unit, pass LPS
* 100% full load burn-in test
* Low cost, high reliability
* Suitable for LED lighting and moving sign applications (Note.7)
* 2 years warranty
Specifications:
MODEL
|
LPC-60-1050
|
LPC-60-1400
|
LPC-60-1750
|
OUTPUT
|
DC VOLTAGE
|
9 ~ 48V
|
9 ~ 42V
|
9 ~ 34V
|
RATED CURRENT
|
1050mA
|
1400mA
|
1750mA
|
RATED POWER
|
50.4W
|
58.8W
|
59.5W
|
RIPPLE & NOISE (max.) Note.2
|
200mVp-p
|
200mVp-p
|
200mVp-p
|
VOLTAGE TOLERANCE Note.3
|
5.0%
|
LINE REGULATION
|
1.0%
|
LOAD REGULATION
|
2.0%
|
SETUP, RISE TIME
|
500ms, 120ms / 230VAC 500ms, 120ms / 115VAC at full load
|
HOLD UP TIME (Typ.)
|
50ms/230VAC 16ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 264VAC 127 ~ 370VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
POWER FACTOR
|
|
EFFICIENCY (Typ.)
|
87%
|
85%
|
87%
|
AC CURRENT (Typ.)
|
1.2A/115VAC 0.7A/230VAC
|
INRUSH CURRENT (Typ.)
|
COLD START 30A/115VAC 60A/230VAC
|
LEAKAGE CURRENT
|
0.25mA / 240VAC
|
PROTECTION
|
CURRENT LIMIT
|
5% rated output current
|
Protection type : Constant current limiting type
|
SHORT CIRCUIT
|
Hiccup mode, recovers automatically after fault condition is removed
|
OVER VOLTAGE
|
50.4 ~ 60V
|
44.1 ~ 56.7V
|
39.1 ~ 45.9V
|
Protection type : Shut off o/p voltage, clamping by zener diode
|
OVER TEMPERATURE
|
|
|
ENVIRONMENT
|
WORKING TEMP.
|
-30 ~ +70 (Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-40 ~ +80 , 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.03%/ (0 ~ 50 )
|
VIBRATION
|
10 ~ 500Hz, 2G 12min./1cycle, period for 60min. each along X, Y, Z axes
|
SAFETY &EMC(Note 4)
|
SAFETY STANDARDS
|
UL1310 Class 2, CAN/CSA C22.2 No. 223-M91(for LPC-60-1750 only), IP67 approved ; design refer to TUV EN60950-1, EN61347-2-13
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55022 (CISPR22) Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2 Class A, EN61000-3-3
|
EMS
IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
|
OTHERS
|
MTBF
|
732Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
162.5*42.5*32mm (L*W*H)
|
PACKING
|
0.4Kg; 32pcs/13.8Kg/0.56CUFT
|