Features:
*  Constant voltage design
*  Universal AC input / Full range
*  Fully encapsulated with IP67 level
*  Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage Fully isolated plastic case
*  Cooling by free air convection
*  UL1310 Class 2 power unit, pass LPS
*  100% full load burn-in test
*  Low cost, high reliability
*  Suitable for LED lighting and moving sign applications (Note.7)
*  2 years warranty

Specifications

MODEL

LPV-60-5

LPV-60-12

LPV-60-15   

LPV-60-24   

LPV-60-36

LPV-60-48

 

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

36V

48V

CURRENT RANGE

0 ~ 8A

0 ~ 5A     

0 ~ 4A

0 ~ 2.5A  

0 ~ 1.67A    

0 ~ 1.25A

RATED CURRENT

8A

5A

4A

2.5A

1.67A

1.25A

RATED POWER

40W

60W

60W

60W

60W

60W

RIPPLE & NOISE 

80mVp-p   

120mVp-p

120mVp-p   

150mVp-p

150mVp-p

150mVp-p

VOLTAGE TOLERANCE 

8.0%

5.0%

LINE REGULATION

1.0%

LOAD REGULATION

6.0%

2.0%

SETUP, RISE TIME

500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V)

HOLD UP TIME

50ms/230VAC  16ms/115VAC at full load

 

 

 

 

INPUT

VOLTAGE RANGE

90 ~ 264VAC 127 ~ 370VDC

FREQUENCY

47 ~ 63Hz

POWER FACTOR

 

EFFICIENCY

76%

83%

83%

86%

86%

86%

AC CURRENT

1.2A/115VAC 1A/230VAC

INRUSH CURRENT

COLD START 30A/115VAC 60A/230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

PROTECTION

OVER CURRENT

110 ~ 150% rated output power

  Protection type : Hiccup mode, recovers automatically after fault condition is removed

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

  5.75 ~ 6.75V  

13.8 ~ 16.2V  

17.25 ~ 20.25V

27.6 ~ 32.4V

41.4 ~ 48.6V  

55.2 ~ 64.8V

Protection type : Shut down o/p voltage, re-power on to recover

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +70 (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 50 )

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for  60min. each along X, Y, Z axes

 

 

 

 

 

SAFETY &EMC

SAFETY STANDARDS

UL1310 Class 2(except for LPV-60-5), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), IP67 approved ; design refer to TUV EN60950-1, EN61347-2-13

WITHSTAND VOLTAGE  

I/P-O/P:3KVAC

ISOLATION RESISTANCE

I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH

EMI CONDUCTION & RADIATION

Compliance to EN55022 (CISPR22) Class B

HARMONIC CURRENT

Compliance to EN61000-3-2 Class A, EN61000-3-3

EMS 

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level,  criteria A

 

OTHERS

MTBF

732Khrs min. MIL-HDBK-217F (25 )

DIMENSION

162.5*42.5*32mm (L*W*H)

PACKING  

0.4Kg; 32pcs/13.8Kg/0.56CUFT