MODEL
|
ASP-150-12
|
ASP-150-15
|
ASP-150-20
|
ASP-150-24
|
ASP-150-48
|
OUTPUT
|
DC VOLTAGE
|
12V
|
15V
|
20V
|
24V
|
48V
|
RATED CURRENT
|
11A
|
9.5A
|
7.5A
|
6.3A
|
3.2A
|
CURRENT RANGE
|
0 ~ 11A
|
0 ~ 9.5A
|
0 ~ 7.5A
|
0 ~ 6.3A
|
0 ~ 3.2A
|
RATED POWER (max.)
|
132W
|
142.5W
|
150W
|
151.2W
|
153.6W
|
RIPPLE & NOISE (max.)
|
150mVp-p
|
180mVp-p
|
200mVp-p
|
240mVp-p
|
240mVp-p
|
VOLTAGE ADJ. RANGE
|
11 ~ 13.2V
|
14 ~ 17V
|
17 ~ 22V
|
22 ~ 27V
|
45.6 ~ 52.8V
|
Fixed. Can be modified between the range above by factory
|
VOLTAGE TOLERANCE
|
2.0%
|
2.0%
|
1.0%
|
1.0%
|
1.0%
|
LINE REGULATION
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
0.5%
|
LOAD REGULATION
|
1.0%
|
1.0%
|
0.5%
|
0.5%
|
0.5%
|
SETUP, RISE TIME
|
3000ms, 80ms at full load
|
HOLD UP TIME
|
50ms/230VAC 16ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 264VAC 127 ~ 370VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
POWER FACTOR (Typ.)
|
PF 0.95/230VAC PF 0.98/115VAC at full load
|
EFFICIENCY (Typ.)
|
88%
|
88%
|
90%
|
90%
|
89%
|
AC CURRENT (Typ.)
|
2A/115VAC 1A/230VAC
|
INRUSH CURRENT (Typ.)
|
COLD START 80A/230VAC
|
LEAKAGE CURRENT
|
<2mA / 240VAC
|
PROTECTION
|
OVER LOAD
|
105 ~ 135% rated output power
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
OVER TEMPERATURE
|
90 10 (RTH2) detect on heatsink of power transistor
|
Protection type : Shut down o/p voltage, re-power on to recover
|
OVER VOLTAGE
|
13.7 ~ 16.2V
|
17.5 ~ 20.25V
|
22.5 ~ 28V
|
27.5 ~ 32.4V
|
53.3 ~ 64.8V
|
Protection type : Shut down o/p voltage, re-power to recover
|
ENVIRONMENT
|
WORKING TEMP.
|
-20 ~ +60oC (Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-20 ~ +85 oC, 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.05%/oC (0 ~ 50oC )
|
VIBRATION
|
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
SAFETY &EMC
|
SAFETY STANDARDS
|
UL60950-1, CB(IEC60950-1) approved
|
WITHSTAND VOLTAGE
|
I/P-O/P:4.25KVDC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55022 (CISPR22) Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2,-3
|
EMS
IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
|
MTBF
|
149.3Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
169*60.7*28.5mm (L*W*H)
|
PACKING
|
0.32Kg; 48pcs/15.8Kg/0.79CUFT
|
NOTE
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. HS1,HS2 & HS3 can not be shorted.
6. Derating may be needed under low input voltages. Please check the derating curve for more details.
7. The rated power includes 5Vsb @ 0.6A.
8. The rated power includes 5Vsb @ 0.8A.
|