MODEL
|
NED-50A
|
NED-50B
|
OUTPUT
|
OUTPUT NUMBER
|
CH1
|
CH2
|
CH1
|
CH2
|
DC VOLTAGE
|
5V
|
12V
|
5V
|
24V
|
CURRENT RANGE
|
1 ~ 6A
|
0.3 ~ 3A
|
1 ~ 6A
|
0.2 ~ 2A
|
RATED CURRENT
|
6A
|
2A
|
4A
|
1.4A
|
RATED POWER
|
54W
|
53.6W
|
RIPPLE & NOISE
|
80mVp-p
|
120mVp-p
|
80mVp-p
|
200mVp-p
|
VOLTAGE ADJ. RANGE
|
CH1: 4.75 ~ 5.5V
|
CH1: 4.75 ~ 5.5V
|
VOLTAGE TOLERANCE
|
2.0%
|
6.0%
|
2.0%
|
6.0%
|
LINE REGULATION
|
0.5%
|
1.0%
|
0.5%
|
1.0%
|
LOAD REGULATION
|
1.5%
|
3.0%
|
1.5%
|
3.0%
|
SETUP RISE TIME
|
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
|
HOLD UP TIME
|
50ms/230VAC 10ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
85 ~ 264VAC 120 ~ 370VDC
|
FREQUENCY
|
47 ~ 63Hz
|
EFFICIENCY
|
79%
|
82%
|
AC CURRENT
|
1.1A/115VAC 0.65A/230VAC
|
INRUSH CURRENT
|
COLD START 45A
|
LEAKAGE CURRENT
|
<2mA / 240VAC
|
PROTECTION
|
OVER LOAD
|
110 ~ 150% rated output power
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed
|
OVER VOLTAGE
|
CH1: 5.75 ~ 6.75V
|
Protection type : Shut down o/p voltage, re-power on to recover
|
ENVIRONMENT
|
WORKING TEMP.
|
-20 ~ +60oC (Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 90% RH non-condensing
|
STORAGE TEMP HUMIDITY
|
-40 ~ +85oC , 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.03%/oC (0 ~ 45oC )
|
VIBRATION
|
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
SAFETY &EMC
|
SAFETY STANDARDS
|
UL60950-1, CB(IEC60950-1) Approved
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55022 (CISPR22) Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2,-3
|
EMS
IMMUNITY
|
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1 Light industry level, criteria A
|
OTHERS
|
MTBF
|
413.3K hrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
129*98*38mm (L*W*H)
|
PACKING
|
0.44Kg; 45pcs/21Kg/1.24CUFT
|
NOTE
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can not exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
|