Mean well HVGC-100 100W Single Output Switching Power Supply

Features:
*  Wide input range 180~480VAC
*  Buit-in active PFC function
*  High efficiency up to 91%
*  Protections:Short circuit/Overload /Over temperature
*  Cooling by free air convection
*  OCP point adjustasble through output cable .or internal potential meter
*  IP67 / IP65 desgn for indoor .or outdoor installations
*  Three in one dimming function (0~10VDC .or 10V PWM signal .or resistance)
*  Suitable for LED lighting and street lighring applications
*  Compliance to worldwide safety regulations for lighting 


Specifications:

MODEL

HVGC-100-350

HVGC-100-700

 

RATED CURRENT

350mA

700mA

RATED POWER

99.75W

99.4W

RIPPLE & NOISE

3Vp-p

1.5Vp-p

VOLTAGE ADJ.RANGE 

210 ~ 350mA

420 ~ 700mA

CURRENT ADJ.RANGE

Can be adjusted by internal potential meter .or through output cable

SETUP, RISE TIME

4000ms, 3000ms at full load 440VAC / 347VAC ; B type 5000ms, 500ms at 95% load 440VAC / 347VAC

HOLD UP TIME 

12ms at full load     440VAC / 347VAC

INPUT

VOLTAGE RANGE

200 ~ 480VAC 282VDC ~ 679VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF>= 0.95/440VAC PF >=0.98/347VAC at full load and rated output voltage PF 0.9 at 60 ~ 100% load

EFFICIENCY

92%

92%

AC CURRENT 

0.32A / 347VAC          0.25A / 440VAC

INRUSH CURRENT 

COLD START 75A / 440VAC

LEAKAGE CURRENT

<0.75mA / 440VAC

PROTECTION

OVERCURRENT

95 ~ 108%

Protection type : Constant current limiting, recovers automatically after fault condition is removed

OVER VOLTAGE

305 ~ 315V

152 ~ 160V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

100oC   10  (RTH2)

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

SHORT CIRCUIT

Constant current limiting, recovers automatically after fault condition is removed

ENVIRO

NMENT

WORKING TEMP.

-40 ~ +60 oC @ full load ; +70oC  @ 60% load (Refer to derating curve)

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80 oC , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/oC  (0 ~ 50oC  )

VIBRATION

10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY &EMC

SAFETY STANDARDS

UL8750, IP65 .or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1, EN61347-1, EN61347-2-13

WITHSTAND VOLTAGE 

I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH

HARMONIC CURRENT

Compliance to EN61000-3-2,CLASS C( 60% load),EN61000-3-3

EMS

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A

OTHERS

MTBF

Khrs min.      MIL-HDBK-217F (25 )

DIMENSION

234*68*38.8mm (L*W*H)

PACKING 

Kg