MODEL
|
LDD-300L
|
LDD-350L
|
LDD-500L
|
LDD-600L
|
LDD-700L
|
OUTPUT
|
DC VOLTAGE
|
2 ~ 32VDC
|
RATED CURRENT
|
300mA
|
350mA
|
500mA
|
600mA
|
700mA
|
RIPPLE & NOISE
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
200mVp-p
|
200mVp-p
|
SWITCHING FREQENCY
|
40KHz ~ 1000KHz
|
CURRENT ACCURACY
|
5% at 24VDC input
|
EXTERNAL CAPACITANCE LOAD
|
2.2uF
|
INPUT
|
VOLTAGE RANGE
|
9~ 36VAC
|
EFFICIENCY
|
95% at full load and 24VDC/48VDC input
|
DC CURRENT
|
Full load Note.3
|
300mA
|
350mA
|
500mA
|
600mA
|
700mA
|
No load
|
10mA
|
FILTER
|
Capacitor
|
PWM
DIMMING
&
ON/OFF
CONTROL
|
REMOTE ON/OFF
|
Leave open if not use
|
Power ON with dimming: DIM ~ -Vin >3.5 ~ 8VDC .or open circuit
|
Power OFF : DIM ~ -Vin < 0.5VDC .or short
|
QUIESCENT INPUT CURRENT
|
1mA at PWM dimming OFF and 24VDC input
|
PWM FREQUENCY
|
100 ~ 1KHz
|
SHORT CIRCUIT
|
Regulated at rated output current
|
Protection type: Can be continued, recovers automatically after fault condition is removed
|
OVER TEMP
|
Tj 150 typically(IC1) detect on main control IC
|
Protection type : Shut down, recovers automatically after temperature goes down
|
ENVIRO
NMENT
|
WORKING TEMP.
|
-40 ~ +85oC (Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 95% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-55 ~ +125 oC, 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.03%/ oC
|
VIBRATION
|
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
|
OPERATING CASE TEMP.
|
100
|
EMC
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55015, FCC part 15 class B
|
EMS IMMUNITY
|
Compliance to EN61000-4-2,3,4,6,8, light industry level, criteria A
|
OTHERS
|
MTBF
|
2000Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
22.6*9.9*8.9mm .or 0.89"*0.39"*0.33" inch (L*W*H)
|
PACKING
|
4g
|
POTTING MATERIAL
|
Expoxy(UL94-V0)
|
NOTE
|
1.All parameters are specified at normal input(48VDC), rated load, 25oC 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf capacitor.
3.Test condition: 48VDC input.
|