Features:
* Universal AC input / Full range
* High efficiency 90%
* Protections: Short circuit / Overload / Over voltage / Over temperature
* Built-in active PFC function
* UL1310 Class 2 power unit
* Pass LPS
* Cooling by free air convection
* 100% full load burn-in test
* High reliability
* Suitable for LED lighting and moving sign applications
* Compliance to worldwide safety regulations for lighting
* 2 years warranty
Specifications:
MODEL
|
PLC-100-12
|
PLC-100-15
|
PLC-100-20
|
PLC-100-24
|
PLC-100-27
|
PLC-100-36
|
PLC-100-48
|
OUTPUT
|
DC VOLTAGE
|
12V
|
15V
|
20V
|
24V
|
27V
|
36V
|
48V
|
C&C REGION
|
9 ~ 12V
|
11.25 ~15V
|
15 ~ 20V
|
18 ~24V
|
20.25 ~27V
|
27 ~ 36V
|
36 ~ 48V
|
CURRENT RANGE
|
0 ~ 5A
|
0 ~ 5A
|
0 ~ 4.8A
|
0 ~ 4A
|
0 ~ 3.55A
|
0 ~ 2.65A
|
0 ~ 2A
|
RATED CURRENT
|
5A
|
5A
|
4.8A
|
4A
|
3.55A
|
2.65A
|
2A
|
RATED POWER
|
60W
|
75W
|
96W
|
96W
|
95.85W
|
95.4W
|
96W
|
RIPPLE & NOISE
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
200mVp-p
|
VOLTAGE ADJ.
|
10.2 ~ 12V
|
12.8 ~ 15V
|
17 ~ 20V
|
20.4 ~ 24V
|
23 ~ 27V
|
30.6 ~ 36V
|
40.8 ~ 48V
|
CURRENT ADJ.
|
3.75 ~ 5A
|
3.75 ~ 5A
|
3.6 ~ 4.8A
|
3 ~ 4A
|
2.6 ~ 3.55A
|
2 ~ 2.65A
|
1.5 ~ 2A
|
VOLTAGE TOLERANCE
|
3.0%
|
3.0%
|
3.0%
|
3.0%
|
3.0%
|
2.0%
|
2.0%
|
LINE REGULATION
|
1.0%
|
LOAD REGULATION
|
2.0%
|
SETUP, RISE TIME
|
1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
|
HOLD UP TIME
|
60ms/230VAC 30ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 264VAC 127 ~ 370VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
POWER FACT.or
|
PF>0.95/230VAC PF>0.95/115VAC at full load PF 0.9 at 75 ~ 100% load
|
EFFICIENCY
|
84.5%
|
86.5%
|
90%
|
90%
|
90%
|
90%
|
89%
|
AC CURRENT
|
12V:0.8A/115VAC 0.4A/230VAC 15V:0.9A/115VAC 0.45A/230VAC 20V ~ 48V:1.1A/115VAC 0.55A/230VAC
|
INRUSH CURRENT
|
COLD START 40A/230VAC
|
LEAKAGE CURRENT
|
<0.75mA / 240VAC
|
OTHERS
|
MTBF
|
297.9Khrs min. MIL-HDBK-217F
|
DIMENSION
|
200.5*69.5*35mm (L*W*H)
|
PACKING
|
0.52Kg; 25pcs/14Kg/0.65CUFT
|