MODEL
|
PLN-45-12
|
PLN-45-15
|
PLN-45-20
|
PLN-45-24
|
PLN-45-27
|
PLN-45-36
|
PLN-45-48
|
OUTPUT
|
DC VOLTAGE
|
12V
|
15V
|
20V
|
24V
|
27V
|
36V
|
48V
|
CONSTANT CURRENT OPERATION VOLTAGE Note.5
|
9 ~ 12V
|
11.25 ~15V
|
15 ~ 20V
|
18 ~24V
|
20.25 ~27V
|
27 ~ 36V
|
36 ~ 48V
|
CURRENT RANGE
|
0 ~ 3.8A
|
0 ~ 3A
|
0 ~ 2.3A
|
0 ~ 1.9A
|
0 ~ 1.7A
|
0 ~ 1.25A
|
0 ~ 0.95A
|
RATED CURRENT
|
3.8A
|
3A
|
2.3A
|
1.9A
|
1.7A
|
1.25A
|
0.95A
|
RATED POWER
|
45.6W
|
45W
|
46W
|
45.6W
|
45.9W
|
45W
|
45.6W
|
RIPPLE & NOISE (max.) Note.2
|
2Vp-p
|
2.4Vp-p
|
1.8Vp-p
|
2.7Vp-p
|
2.7Vp-p
|
3.6Vp-p
|
4.6Vp-p
|
VOLTAGE ADJ. RANGE Note.5
|
11.5 ~ 13V
|
14.5 ~ 16.2V
|
19.5 ~ 22V
|
24 ~ 26V
|
25 ~ 30V
|
32.5 ~ 39V
|
43.6 ~ 51.8V
|
Can be adjusted by internal potential meter SVR1
|
CURRENT ADJ.RANGE Note.5
|
3% ~ -25%. Can be adjusted by internal potential meter SVR2
|
VOLTAGE TOLERANCE Note.3
|
10%
|
LINE REGULATION
|
3.0%
|
LOAD REGULATION
|
5.0%
|
SETUP, RISE TIME
|
1500ms / 230VAC 3000ms / 115VAC at full load
|
HOLD UP TIME (Typ.)
|
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 295VAC 127 ~ 417VDC
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
POWER FACTOR
|
PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC
|
EFFICIENCY (Typ.)
|
83.5%
|
85%
|
86.5%
|
86.5%
|
86.5%
|
87.5%
|
87.5%
|
AC CURRENT (Typ.)
|
0.55A/115VAC 0.25A/230VAC
|
INRUSH CURRENT (Typ.)
|
40A/230VAC
|
LEAKAGE CURRENT
|
<0.75mA / 240VAC
|
PROTECTION
|
OVER CURRENT
|
95 ~ 110%
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed
|
SHORT CIRCUIT
|
Hiccup mode, recovers automatically after fault condition is removed.
|
OVER VOLTAGE
|
13.8 ~ 16V
|
17.5 ~ 21V
|
22.8 ~ 25V
|
28 ~ 32V
|
31 ~ 35V
|
41 ~ 46V
|
54 ~ 60V
|
Protection type : Shut down o/p voltage, re-power on to recover
|
OVER TEMPERATURE
|
95 10 (TSW1) detect on heatsink of power transistor
|
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
|
ENVIRONMENT
|
WORKING TEMP.
|
-30 ~ +50 (Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 95% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-40 ~ +80 , 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
0.03%/ (0 ~ 50 )
|
VIBRATION
|
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
SAFETY &EMC(Note 4)
|
SAFETY STANDARDS
|
UL879, UL8750, UL1310 Class 2, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved
|
WITHSTAND VOLTAGE
|
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P:100M Ohms/500VDC / 25 / 70%RH
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55015
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
|
EMS
IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11; En61547, light industry level, criteria A
|
OTHERS
|
MTBF
|
497.8Khrs min. MIL-HDBK-217F (25 )
|
DIMENSION
|
181*61.5*35mm (L*W*H)
|
PACKING
|
0.5Kg; 24pcs/13Kg/0.75CUFT
|